CoChat

Pulmonary Vein Antral Isolation for Paroxysmal Atrial Fibrillation: Results from Long-Term Follow-Up: Medi et al. Long-Term Follow-Up After Atrial Fibrillation Ablation

MEDI, C., SPARKS, P.B., MORTON, J.B., KISTLER, P.M., HALLORAN, K., ROSSO, R., VOHRA, J.K., KUMAR, S., KALMAN, J.M. · 2010 · Journal of Cardiovascular Electrophysiology
Cited by 150

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Pulmonary veins play an important role in triggering atrial fibrillation (AF). Pulmonary vein isolation (PVI) is an effective treatment for patients with paroxysmal AF. However, the late AF recurrence rate in long-term follow-up of circumferential PV antral isolation (PVAI) is not well documented. We sought to determine the time to recurrence of arrhythmia after PVAI, and long-term rates of sinus rhythm after circumferential PVAI. METHODS: One hundred consecutive patients with a mean age of 54 ± 10 years, with paroxysmal AF who underwent PVAI procedure were analyzed. Isolation of pulmonary veins was based on an electrophysiological and anatomical approach, with a nonfluoroscopic navigation mapping system to guide antral PVI. Ablation endpoint was vein isolation confirmed with a circular mapping catheter at first and subsequent procedures. Clinical, ECG, and Holter follow-up was undertaken every 3 months in the first year postablation, every 6 months thereafter, with additional prolonged monitoring if symptoms were reported. Time to arrhythmia recurrence, and representing arrhythmias, were documented. RESULTS: Isolation of all 4 veins was successful in 97% patients with 3.9 ± 0.3 veins isolated/patient. Follow-up after the last RF procedure was at a mean of 39 ± 10 months (range 21-66 months). After a single procedure, sinus rhythm was maintained at long-term follow-up in 49% patients without use of antiarrhythmic drugs (AADs). After repeat procedure, sinus rhythm was maintained in 57% patients without the use of AADs, and in 82% patients including patients with AADs. A total of 18 of 100 patients had 2 procedures and 4 of 100 patients had 3 procedures for recurrent AF/AT. Most (86%) AF/AT recurrences occurred ≤ 1 year after the first procedure. Mean time to recurrence was 6 ± 10 months. Kaplan-Meier analysis on antiarrhythmics showed AF free rate of 87% at 1 year and 80% at 4 years. There were no major complications. CONCLUSION: PVAI is an effective strategy for the prevention of AF in the majority of patients with PAF. Maintenance of SR requires repeat procedure or continuation of AADs in a significant proportion of patients. After maintenance of sinus rhythm 1-year post-PVAI, a minority of patients will subsequently develop late recurrence of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2010.01885.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 150

Metadata

Authors
MEDI, C., SPARKS, P. B., MORTON, J. B., KISTLER, P. M., HALLORAN, K., ROSSO, R., VOHRA, J. K., KUMAR, S., & KALMAN, J. M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2010-08-31
Volume
22
Issue
2
Pages
no-no
ISSN
1045-3873 (ISSN-L)
OpenAlex
W2124203956
Cited by
150
References
1
FWCI
10.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.