Preprocedural Predictors of Atrial Fibrillation Recurrence Following Pulmonary Vein Antrum Isolation in Patients With Paroxysmal Atrial Fibrillation: Long-Term Follow-Up Results
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The objective of this study was to identify the simple preprocedural parameters of atrial fibrillation (AF) recurrence following single ablation procedure in patients with paroxysmal AF during long-term follow-up period. METHODS AND RESULTS: Consecutive 474 patients (61 ± 10 years; 364 males, left atrial (LA) diameter 37.6 ± 5.1 mm) with drug-refractory paroxysmal AF who underwent AF ablation were analyzed. Pulmonary vein antrum isolation (PVAI), cavotricuspid isthmus line creation with bidirectional conduction block, and elimination of all non-PV triggers of AF were performed in all patients. With a mean follow-up of 30 ± 13 months after single procedure, 318 patients (67.1%) were in sinus rhythm without any antiarrhythmic drugs. Multivariate analysis using Cox's proportional hazards model, including the age, gender, duration of AF, body mass index, LA size, left ventricular ejection fraction, and presence of hypertension and structural heart disease as variables, demonstrated that LA size was an independent predictor of AF recurrences after PVAI with a 7.2% increase in the probability for every 1 mm increase in LA diameter (P = 0.0007). When the patients were categorized into 3 groups according to the LA diameter, the patients with moderate (40-50 mm) and severe dilatation (>50 mm) had a 1.30-fold (P = 0.0131) and 2.14-fold (P = 0.0057) increase, respectively, in the probability of recurrent AF as compared with the patients with normal LA diameter (≤40 mm). CONCLUSION: In the long-term follow-up period, LA size was the best preprocedural predictor of AF recurrence following single ablation procedure in the patients with paroxysmal AF, even in the patients with a relatively small LA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Body Mass Index, Obstructive Sleep Apnea, and Outcomes of Catheter Ablation of Atrial Fibrillation
JONGNARANGSIN, K., CHUGH, A., GOOD, E., MUKERJI, S., DEY, S., CRAWFORD, T., SARRAZIN, J. F., KUHNE, M., CHALFOUN, N., WELLS, D., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01118.x · Cited by 219
A novel pacing maneuver to localize focal atrial tachycardia
MOHAMED, U., SKANES, A. C., GULA, L. J., LEONG‐SIT, P., KRAHN, A. D., YEE, R., SUBBIAH, R., & KLEIN, G. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00664.x · Cited by 164
Catheter ablation for atrial fibrillation in patients with obesity
Cha, Y.-M., Friedman, P. A., Asirvatham, S. J., Shen, W.-K., Munger, T. M., Rea, R. F., Brady, P. A., Jahangir, A., Monahan, K. H., Hodge, D. O., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.716712 · Cited by 110
Cited by
Pokushalov, E., Romanov, A., Corbucci, G., Artyomenko, S., Baranova, V., Turov, A., Shirokova, N., Karaskov, A., Mittal, S., & Steinberg, J. S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.036 · Cited by 432
Njoku, A., Kannabhiran, M., Arora, R., Reddy, P., Gopinathannair, R., Lakkireddy, D., & Dominic, P. (2018) · EP Europace · doi:10.1093/europace/eux013 · Cited by 419
D'Ascenzo, F., Corleto, A., Biondi-Zoccai, G., Anselmino, M., Ferraris, F., di Biase, L., Natale, A., Hunter, R. J., Schilling, R. J., Miyazaki, S., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.05.008 · Cited by 216
“From the 3475 citations first screened, 27 complete reports were evaluated for inclusion in the present research and finally 19 studies were included in the review [14–33] (Fig.”
BackgroundSelf-citationDifferences in catheter ablation of paroxysmal atrial fibrillation between males and females
Takigawa, M., Kuwahara, T., Takahashi, A., Watari, Y., Okubo, K., Takahashi, Y., Takagi, K., Kuroda, S., Osaka, Y., Kawaguchi, N., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.101 · Cited by 106
“[11,12].”
Self-citationDzeshka, M. S., Shahid, F., Shantsila, A., & Lip, G. Y. H. (2017) · American Journal of Hypertension · doi:10.1093/ajh/hpx013 · Cited by 91
Metadata
- Authors
- MIYAZAKI, S., KUWAHARA, T., KOBORI, A., TAKAHASHI, Y., TAKEI, A., SATO, A., ISOBE, M., & TAKAHASHI, A.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2011-01-14
- Volume
- 22
- Issue
- 6
- Pages
- 621-625
- ISSN
- 1045-3873 (ISSN-L)
- OpenAlex
- W2005067026
- Cited by
- 81
- References
- 3
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preprocedural Predictors of Atrial Fibrillation Recurrence Following Pulmonary Vein Antrum Isolation in Patients With Paroxysmal Atrial Fibrillation: Long-Term Follow-Up Results. https://app.cochat.ai/papers/10.1111/j.1540-8167.2010.01984.x
- The paper
- MIYAZAKI, S., KUWAHARA, T., KOBORI, A., TAKAHASHI, Y., TAKEI, A., SATO, A., ISOBE, M., & TAKAHASHI, A. (2011). Preprocedural Predictors of Atrial Fibrillation Recurrence Following Pulmonary Vein Antrum Isolation in Patients With Paroxysmal Atrial Fibrillation: Long-Term Follow-Up Results. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2010.01984.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.