Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Direct Ultrasound Measurement of Longitudinal, Circumferential, and Radial Strain Using 2‐Dimensional Strain Imaging in Normal Adults

Hurlburt, Heather M., Aurigemma, Gerard P., Hill, Jeffrey C., Narayanan, Arumugam, Gaasch, William H., Vinch, Craig S., Meyer, Theo E., Tighe, Dennis A. · 2007 · Echocardiography

Abstract

Current noninvasive techniques used to evaluate left ventricular systolic function are limited by dependence on the angle of insonation (tissue Doppler imaging/TDI) or limited by availability (MRI tagging). We utilized 2‐dimensional speckle strain (ε) imaging (1) to establish normal values for all three ε vectors; (2) to compare circumferential ε values with circumferential shortening (midwall fractional shortening (FS mw); (3) to examine the relationship between left ventricular ε and wall stress; and (4) to compare 2D echocardiographic characteristics by gender. Echocardiography was performed in 60 normal subjects (mean 39 ± 15 years). Small, but significant regional heterogeneity was seen in circumferential ε, but not in radial or longitudinal ε. We found an inverse correlation between circumferential ε and stress (r =−0.29, p<0.05) as well as longitudinal ε and stress (r =−0.11, P < 0.05), though the relationships were not close. We also observed a linear relationship between mean circumferential ε and FS mw (r = 0.29, P < 0.05). In conclusion, (1) 2‐dimensional ε imaging permits measurement of regional systolic ε values in the majority of normal individuals; (2) ε values furnished by this method obey expected stress‐shortening relationships; (3) systolic ε displays minor regional heterogeneity in the circumferential direction; (4) for the first time, a close relationship between FS mw and mean circumferential ε was demonstrated; and (5) there are minor gender‐related differences in LV geometry and function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8175.2007.00460.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 178

Metadata

Authors
Hurlburt, H. M., Aurigemma, G. P., Hill, J. C., Narayanan, A., Gaasch, W. H., Vinch, C. S., Meyer, T. E., & Tighe, D. A.
Venue
Echocardiography
Publisher
Wiley
Published
2007-05-14
Volume
24
Issue
7
Pages
723-731
ISSN
  • 0742-2822 (ISSN-L)
  • 1540-8175
OpenAlex
W2020631906
Cited by
178
References
2
FWCI
8.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Ultrasound Measurement of Longitudinal, Circumferential, and Radial Strain Using 2‐Dimensional Strain Imaging in Normal Adults. https://app.cochat.ai/papers/10.1111/j.1540-8175.2007.00460.x
The paper
Hurlburt, H. M., Aurigemma, G. P., Hill, J. C., Narayanan, A., Gaasch, W. H., Vinch, C. S., Meyer, T. E., & Tighe, D. A. (2007). Direct Ultrasound Measurement of Longitudinal, Circumferential, and Radial Strain Using 2‐Dimensional Strain Imaging in Normal Adults. Echocardiography. https://doi.org/10.1111/j.1540-8175.2007.00460.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.