Magnetocardiographically‐Guided Catheter Ablation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
After more than 30 years since the first magnetocardiographic (MCG) recording was carried out with induction coils, MCG is now approaching the threshold of clinical use. During the last 5 years, in fact, there has been a growing interest of clinicians in this new method which provides an unrivalled accuracy for noninvasive, three‐dimensional localization of intracardiac source. An increasing number of laboratories are reporting data validating the use of MCG as an effective method for preoperative localization of arrhythmogenic substrates and for planning the best catheter ablation approach for different arrhythmogenic substrates. In this article, available data from literature have been reviewed. We consider the clinical use of MCG to localize arrhythmogenic substrates in patients with Wolff‐Parkinson‐White syndrome and in patients with ventricular tachycardia in order to assess the state‐of‐the‐art of the method on a large number of patients. This article also addresses some suggestions for industrial development of more compact, medically oriented MCG equipments at reasonable cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of a superconducting instrumentation for biomagnetic measurements performed in a hospital
Barbanera, S., Carelli, P., Fenici, R., Leoni, R., Modena, I., & Romani, G. (1981) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1981.1061052 · Cited by 29
Self-citationClinical magnetocardiography: 10 Years experience at the catholic university
Fenici, R. R., Melillo, G., & Masselli, M. (1991) · The International Journal of Cardiac Imaging · doi:10.1007/bf01797748 · Cited by 23
Self-citationMagnetocardiography: clinical investigations with a biomagnetic multichannel system
Achenbach, S., & Moshage, W. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/4a/011 · Cited by 20
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Self-citationFENICI, R., NENONEN, J., PESOLA, K., KORHONEN, P., LÖTJÖNEN, J., MÄKIJÄRVI, M., TOIVONEN, L., POUTANEN, V., KETO, P., & KATILA, T. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00602.x · Cited by 29
Self-citationFENICI, R., PESOLA, K., KORHONEN, P., MÄKIJÄRVI, M., NENONEN, J., TOIVONEN, L., FENICI, P., & KATILA, T. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01207.x · Cited by 22
Self-citationFENICI, R., PESOLA, K., MÄKIJÄRVI, M., NENONEN, J., TEENER, U., FENICI, P., & KATILA, T. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01206.x · Cited by 19
Self-citation
Metadata
- Authors
- FENICI, R. R., COVINO, M., CELLERINO, C., DI LILLO, M., DE FILIPPO, M. C., & MELILLO, G.
- Venue
- Journal of Interventional Cardiology
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 8
- Issue
- s6
- Pages
- 825-836
- ISSN
- 0896-4327 (ISSN-L)
- 1540-8183
- OpenAlex
- W2171463641
- Cited by
- 9
- References
- 3
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiographically‐Guided Catheter Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8183.1995.tb00936.x
- The paper
- FENICI, R. R., COVINO, M., CELLERINO, C., DI LILLO, M., DE FILIPPO, M. C., & MELILLO, G. (1995). Magnetocardiographically‐Guided Catheter Ablation. Journal of Interventional Cardiology. https://doi.org/10.1111/j.1540-8183.1995.tb00936.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.