CoChat

Noninvasive Electrocardiographic Imaging

Rudy, Yoram, Burnes, John E. · 1999 · Annals of Noninvasive Electrocardiology
Cited by 108

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background:Cardiac arrhythmias continue to be a leading cause of death and disability. Despite this alarming fact, a noninvasive imaging modality for cardiac electrophysiology (EP) has not been developed. Standard electrocardiographic techniques attempt to infer electrophysiological processes in the heart from a limited number of recordings on the body surface. This traditional approach is limited in its ability to provide information on regional electrocardiac activity and to localize electrophysiological events in the heart (e.g., arrhythmogenic foci; regions of elevated dispersion of myocardial repolarization). This article reviews the development of a novel imaging modality (electrocardiographic imaging [ECGI]) for the reconstruction of cardiac electrical activity from potentials measured away from the heart (i.e., on the torso surface). The results presented demonstrate that ECGI can noninvasively reconstruct epicardial potentials, electrograms, and isochrones with good accuracy and resolution. Results:The locations of ectopic pacing sites are reconstructed within 10 mm of their actual positions. Dual epicardial pacing sites separated by 52 mm, 35 mm, and 17 mm can be resolved. The depth of intramural ectopic activity can be estimated and the direction of intramural activation spread can be determined from the reconstructed epicardial potential pattern and its evolution in time. Results from infarcted hearts demonstrate that ECGI can detect and reconstruct the abnormal electrophysiological substrate associated with the infarct. The figure‐of‐eight pattern of reentrant activation in the epicardial border zone during ventricular tachycardia is also reconstructed by ECGI noninvasively. Conclusions:These results demonstrate the potential of ECGI as a clinical noninvasive imaging modality for identifying patients at risk of cardiac arrhythmias and for guiding and evaluating antiarrhythmic interventions in such patients. A.N.E. 1999;4(3):340–359

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1542-474x.1999.tb00220.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 108

Metadata

Authors
Rudy, Y., & Burnes, J. E.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
1999-07
Volume
4
Issue
3
Pages
340-359
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W2085606121
Cited by
108
References
1
FWCI
0.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Electrocardiographic Imaging. https://app.cochat.ai/papers/10.1111/j.1542-474x.1999.tb00220.x
The paper
Rudy, Y., & Burnes, J. E. (1999). Noninvasive Electrocardiographic Imaging. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/j.1542-474x.1999.tb00220.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.