CoChat

Ectopic Beats in Heart Rate Variability Analysis: Effects of Editing on Time and Frequency Domain Measures

Open access
Salo, Mirja A., Huikuri, Heikki V., Seppanen, Tapio · 2001 · Annals of Noninvasive Electrocardiology
Cited by 134

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Various methods can be used to edit biological and technical artefacts in heart rate variability (HRV), but there is relatively little information on the effects of such editing methods on HRV. Methods: The effects of editing on HRV analysis were studied using R‐R interval data of 10 healthy subjects and 10 patients with a previous myocardial infarction (Ml). R‐R interval tachograms of verified sinus beats were analyzed from short‐term (∼5 min) and long‐term (—24 hours) recordings by eliminating different amounts of real R‐R intervals. Three editing methods were applied to these segments: (1) interpolation of degree zero, (2) interpolation of degree one, and (3) deletion without replacement. Results: In time domain analysis of short‐term data, the standard deviation of normal‐to‐normal intervals (SDANN) was least affected by editing, and 30%‐50% of the data could be edited by all the three methods without a significant error (< 5%). In the frequency domain analysis, the method of editing resulted in remarkably different changes and errors for both the high‐frequency (HF) and the low‐frequency (LF) spectral components. The editing methods also yielded in different results in healthy subjects and AMI patients. In 24‐hour HRV analysis, up to 50% could be edited by all methods without an error larger than 5% in the analysis of the standard deviation of normal to normal intervals (SDNN). Both interpolation methods also performed well in the editing of the long‐term power spectral components for 24‐hour data, but with the deletion method, only 5% of the data could be edited without a significant error. Conclusions: The amount and type of editing R‐R interval data have remarkably different effects on various HRV indices. There is no universal method for editing ectopic beats that could be used in both the time‐domain and the frequency‐domain analysis of HRV. A.N.E. 2001;6(1):5–17

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1542-474x.2001.tb00080.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 134

Metadata

Authors
Salo, M. A., Huikuri, H. V., & Seppanen, T.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2001-01
Volume
6
Issue
1
Pages
5-17
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W2015750049
Cited by
134
References
2
FWCI
2.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ectopic Beats in Heart Rate Variability Analysis: Effects of Editing on Time and Frequency Domain Measures. https://app.cochat.ai/papers/10.1111/j.1542-474x.2001.tb00080.x
The paper
Salo, M. A., Huikuri, H. V., & Seppanen, T. (2001). Ectopic Beats in Heart Rate Variability Analysis: Effects of Editing on Time and Frequency Domain Measures. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/j.1542-474x.2001.tb00080.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.