CoChat

A New Method to Measure Peripheral Retinal Vascular Caliber over an Extended Area

Yim-lui Cheung, Carol, Hsu, Wynne, Lee, Mong Li, Wang, Jie Jin, Mitchell, Paul, Peter Lau, Qiangfeng, Hamzah, Haslina, Ho, Maisie, Wong, Tien Yin · 2010 · Microcirculation
Cited by 109

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To describe a new computer-assisted method to measure retinal vascular caliber over an extended area of the fundus. METHODS: Retinal photographs taken from participants of the Singapore Malay Eye Study (n = 3280) were used for this study. Retinal vascular caliber was measured and summarized as central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) using a new semi-automated computer-based program. Measurements were made at the Standard zone (from 0.5 to 1.0 disk diameter) and an Extended zone (from 0.5 to 2.0 disk diameter). RESULTS: Reliability of retinal vascular caliber measurement was high for the new Extended zone (intraclass correlation coefficients >0.90). Associations of CRAE with blood pressure were identical between the Extended and Standard zones (linear regression coefficient -2.53 vs. -2.61, z-test between the two measurements, p = 0.394). Associations of CRAE and CRVE with other cardiovascular risk factors were similar between measurements in the two zones. The R² of regression models for the Extended zone was slightly higher than that for the Standard zone for both CRAE (R², 0.324 vs. 0.288) and CRVE (R², 0.325 vs. 0.265). CONCLUSIONS: The new measures from Extended zone are comparable with the previous measures, and also more representative of retinal vascular caliber.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1549-8719.2010.00048.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Yim-lui Cheung, C., Hsu, W., Lee, M. L., Wang, J. J., Mitchell, P., Peter Lau, Q., Hamzah, H., Ho, M., & Wong, T. Y.
Venue
Microcirculation
Publisher
Wiley
Published
2010-05
Volume
17
Issue
7
Pages
no-no
ISSN
  • 1073-9688 (ISSN-L)
  • 1549-8719
OpenAlex
W1975605692
Cited by
109
References
0
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Method to Measure Peripheral Retinal Vascular Caliber over an Extended Area. https://app.cochat.ai/papers/10.1111/j.1549-8719.2010.00048.x
The paper
Yim-lui Cheung, C., Hsu, W., Lee, M. L., Wang, J. J., Mitchell, P., Peter Lau, Q., Hamzah, H., Ho, M., & Wong, T. Y. (2010). A New Method to Measure Peripheral Retinal Vascular Caliber over an Extended Area. Microcirculation. https://doi.org/10.1111/j.1549-8719.2010.00048.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.