Multifractal and Lacunarity Analysis of Microvascular Morphology and Remodeling
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Classical measures of vessel morphology, including diameter and density, are employed to study microvasculature in endothelial membrane labeled mice. These measurements prove sufficient for some studies; however, they are less well suited for quantifying changes in microcirculatory networks lacking hierarchical structure. We demonstrate that automated multifractal analysis and lacunarity may be used with classical methods to quantify microvascular morphology. METHODS: Using multifractal analysis and lacunarity, we present an automated extraction tool with a processing pipeline to characterize 2D representations of 3D microvasculature. We apply our analysis on four tissues and the hyaloid vasculature during remodeling. RESULTS: We found that the vessel networks analyzed have multifractal geometries and that kidney microvasculature has the largest fractal dimension and the lowest lacunarity compared to microvasculature networks in the cortex, skin, and thigh muscle. Also, we found that, during hyaloid remodeling, there were differences in multifractal spectra reflecting the functional transition from a space filling vasculature which nurtures the lens to a less dense vasculature as it regresses, permitting unobstructed vision. CONCLUSION: Multifractal analysis and lacunarity are valuable additions to classical measures of vascular morphology and will have utility in future studies of normal, developing, and pathological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Fractal Geometry of Nature
Mandelbrot, B. B., & Wheeler, J. A. (1983) · American Journal of Physics · doi:10.1119/1.13295 · Cited by 21,832
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
The Fractal Geometry of Nature
Mandelbrot, B. B., & Longley, P. (1982) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,293
A General Model for the Origin of Allometric Scaling Laws in Biology
West, G. B., Brown, J. H., & Enquist, B. J. (1997) · Science · doi:10.1126/science.276.5309.122 · Cited by 5,016
The Variation of Certain Speculative Prices
Mandelbrot, B. (1963) · The Journal of Business · doi:10.1086/294632 · Cited by 4,747
The variation of certain speculative prices
Mandelbrot, B. B. (1997) · Fractals and Scaling in Finance · doi:10.1007/978-1-4757-2763-0_14 · Cited by 4,468
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
Fractal and multifractal analysis: A review
Lopes, R., & Betrouni, N. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.05.003 · Cited by 1,030
The multifractal nature of turbulent energy dissipation
Meneveau, C., & Sreenivasan, K. R. (1991) · Journal of Fluid Mechanics · doi:10.1017/s0022112091001830 · Cited by 860
Baish, J. W., & Jain, R. K. (2000) · PubMed · Cited by 714
Lacunarity analysis: A general technique for the analysis of spatial patterns
Plotnick, R. E., Gardner, R. H., Hargrove, W. W., Prestegaard, K., & Perlmutter, M. (1996) · Physical Review E · doi:10.1103/physreve.53.5461 · Cited by 582
Vascular remodeling of the mouse yolk sac requires hemodynamic force
Lucitti, J. L., Jones, E. A. V., Huang, C., Chen, J., Fraser, S. E., & Dickinson, M. E. (2007) · Development · doi:10.1242/dev.02883 · Cited by 483
Self-citationMicrovessel Density as a Prognostic Factor in Women with Breast Cancer
Uzzan, B., Nicolas, P., Cucherat, M., & Perret, G.-Y. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-1957 · Cited by 468
Macrophages are required for cell death and tissue remodeling in the developing mouse eye
Lang, R. A., & Bishop, J. M. (1993) · Cell · doi:10.1016/0092-8674(93)80047-i · Cited by 366
Fractal Analysis of the Vascular Tree in the Human Retina
Masters, B. R. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140100 · Cited by 316
Viewpoint Invariant Texture Description Using Fractal Analysis
Xu, Y., Ji, H., & Fermüller, C. (2009) · International Journal of Computer Vision · doi:10.1007/s11263-009-0220-6 · Cited by 297
Multifractal analysis of human retinal vessels
Stosic, T., & Stosic, B. D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879316 · Cited by 210
Microvessel count predicts metastatic disease and survival in non‐small cell lung cancer
Fontanini, G., Bigini, D., Vignati, S., Basolo, F., Mussi, A., Lucchi, M., Chine, S., Angeletti, C. A., Harris, A. L., & Bevilacqua, G. (1995) · The Journal of Pathology · doi:10.1002/path.1711770110 · Cited by 183 · cited 1×
“Vessel density is the simplest expression of how vessels fill a space [7,12,50] and can be measured from images of vessels by counting the number of pixels that contain part of the vessel image and dividing these by the total number of pixels for a given image [41].”
BackgroundBiomimetic approach to tissue engineering
Grayson, W. L., Martens, T. P., Eng, G. M., Radisic, M., & Vunjak‐Novakovic, G. (2008) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2008.12.008 · Cited by 179 · cited 2×
“Numerous studies have applied this analysis to quantify changes in the vasculature [9,17,31,40,46,48].”
BackgroundMethodFractal analysis of retinal vessels suggests that a distinct vasculopathy causes lacunar stroke
Doubal, F. N., MacGillivray, T. J., Patton, N., Dhillon, B., Dennis, M. S., & Wardlaw, J. M. (2010) · Neurology · doi:10.1212/wnl.0b013e3181d7d8b4 · Cited by 174 · cited 3×
“Numerous studies have applied this analysis to quantify changes in the vasculature [9,17,31,40,46,48].”
BackgroundMethodMicroscopic analysis and significance of vascular architectural complexity in renal cell carcinoma.
Sabo, E., Boltenko, A., Sova, Y., Stein, A., Kleinhaus, S., & Resnick, M. B. (2001) · PubMed · Cited by 164
Retinal Vascular Fractals and Microvascular and Macrovascular Complications in Type 1 Diabetes
Grauslund, J., Green, A., Kawasaki, R., Hodgson, L., Sjølie, A. K., & Wong, T. Y. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2009.10.047 · Cited by 121 · cited 2×
“Already, simple fractal analysis has proven useful in analyzing retinal vessels to differentiate patients with lacunar-type stroke from normal patients [9], to determine macro- and microvascular complications in type 1 diabetes [16], and to follow progression of chronic kidney failure [47].”
BackgroundFibroblast Growth Factor-2 Selectively Stimulates Angiogenesis of Small Vessels in Arterial Tree
Parsons‐Wingerter, P. A., Elliott, K. E., Clark, J. I., & Farr, A. G. (2000) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.20.5.1250 · Cited by 103
Dajnowiec, D., & Langille, B. L. (2007) · Clinical Science · doi:10.1042/cs20060337 · Cited by 100 · cited 1×
“Thus, there are significant changes in vessel architecture during vessel remodeling in development [28,43], in response to physiological changes [3], and as a result of pathology [8].”
BackgroundThe Human Hyaloid System: Cell Death and Vascular Regression
Zhu, M., Madigan, M. C., van Driel, D., Maslim, J., Billson, F. A., Provis, J. M., & Penfold, P. L. (2000) · Experimental Eye Research · doi:10.1006/exer.2000.0844 · Cited by 95
Tissue Engineering and Organ Structure: A Vascularized Approach to Liver and Lung
Hoganson, D. M., Pryor, H. I., & Vacanti, J. P. (2008) · Pediatric Research · doi:10.1203/01.pdr.0000305879.38476.0c · Cited by 77 · cited 1×
“Moreover, for tissue engineering applications, it is important to use quantitative methods to describe vessel structures in order to develop truly biomimetic vascularized scaffolds [17,19].”
BackgroundLarina, I. V., Shen, W., Kelly, O., Hadjantonakis, A., Baron, M. H., & Dickinson, M. E. (2009) · The Anatomical Record · doi:10.1002/ar.20821 · Cited by 77
Self-citationComparative structural and hemodynamic analysis of vascular trees
Yang, J., Yu, L. X., Rennie, M. Y., Sled, J. G., & Henkelman, R. M. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00363.2009 · Cited by 65
Fractal analysis of the retinal vasculature and chronic kidney disease
Sng, C. C. A., Sabanayagam, C., Lamoureux, E. L., Liu, E., Lim, S. C., Hamzah, H., Lee, J., Tai, E. S., & Wong, T. Y. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq007 · Cited by 64
Poché, R. A., Larina, I. V., Scott, M. L., Saik, J. E., West, J. L., & Dickinson, M. E. (2009) · Developmental Dynamics · doi:10.1002/dvdy.21886 · Cited by 39
Self-citationLin, K. Y., Maricevich, M., Bardeesy, N. M., Weissleder, R., & Mahmood, U. (2008) · Translational Oncology · doi:10.1593/tlo.08118 · Cited by 30
Penn, J. S., & Gay, C. A. (1992) · Experimental Eye Research · doi:10.1016/0014-4835(92)90045-t · Cited by 20
Cited by
Aspiration-assisted bioprinting for precise positioning of biologics
Ayan, B., Heo, D. N., Zhang, Z., Dey, M., Povilianskas, A., Drapaca, C., & Ozbolat, I. T. (2020) · Science Advances · doi:10.1126/sciadv.aaw5111 · Cited by 283
Jiang, D., Correa-Gallegos, D., Christ, S., Stefanska, A., Liu, J., Ramesh, P., Rajendran, V., De Santis, M. M., Wagner, D. E., & Rinkevich, Y. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0073-8 · Cited by 181
Leslie-Barbick, J. E., Saik, J. E., Gould, D. J., Dickinson, M. E., & West, J. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.060 · Cited by 174
“Briefly, the fractal dimension quantifies the amount of space filled by an object, and lacunarity quantifies how it fills space [13,17,18].”
BackgroundSelf-citationImproved Angiogenesis in Response to Localized Delivery of Macrophage-Recruiting Molecules
Hsu, C.-W., Poché, R. A., Saik, J. E., Ali, S., Wang, S., Yosef, N., Calderon, G. A., Scott, L., Vadakkan, T. J., Larina, I. V., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131643 · Cited by 56
“To quantify these dramatic structural differences, we performed measurements of the lacunarity parameter to define the space-filling properties of the induced vessel beds [47].”
MethodSelf-citation
Metadata
- Authors
- GOULD, D. J., VADAKKAN, T. J., POCHÉ, R. A., & DICKINSON, M. E.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2011-02
- Volume
- 18
- Issue
- 2
- Pages
- 136-151
- ISSN
- 1073-9688 (ISSN-L)
- OpenAlex
- W1838172443
- Cited by
- 163
- References
- 32
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.