The DOI matches its Crossref record.
Short-axis versus Long-axis Approaches for Teaching Ultrasound-guided Vascular Access on a New Inanimate Model
Open accessAbstract
OBJECTIVES: To determine whether a short-axis (SA) or long-axis (LA) ultrasound (US) approach to guidance for line placement results in faster vascular access for novice US users. Also, to assess if there was a difference in the number of skin penetrations and needle redirections between the two guidance techniques. METHODS: This was a prospective, randomized, observational study of emergency medicine (EM) residents at a Level I trauma center. A gelatin dessert and dietary fiber supplement mixture, providing a realistic US image, were placed inside a synthetic arm skin that is used for training phlebotomists and contains a rubber vein filled with red fluid at a depth of 1.5 cm. After a 30-minute tutorial on US-guided vascular access, EM residents were randomized to one of two groups. Group one attempted SA first and then the LA. Group two tried LA first followed by the SA. Time from skin break to vein cannulation, number of skin breaks and needle redirections, and difficulty of access on a 10-point Likert scale as reported by residents were recorded. Statistical analysis included paired Student's t-test with 95% confidence intervals (95% CIs). RESULTS: Seventeen EM residents participated. The mean times to vein cannulation in SA and LA were 2.36 minutes (95% CI = 1.15 to 3.58) and 5.02 minutes (95% CI = 2.90 to 7.13), respectively (p = 0.03). The mean numbers of skin breaks for SA and LA were 4.18 (95% CI = 1.18 to 7.17) and 5.76 (95% CI = 1.83 to 9.69), respectively (p = 0.49). The mean numbers of needle redirections in the SA and LA were 13.71 (95% CI = 4.51 to 22.89) and 18.17 (95% CI = 7.95 to 28.40), respectively (p = 0.51). The mean difficulty scores for SA and LA were 3.99 (95% CI = 2.42 to 5.67) and 5.86 (95% CI = 4.32 to 7.40), respectively (p = 0.17). CONCLUSIONS: Novice US users obtain vascular access faster with an SA approach on an inanimate model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834
Self-citationFrankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Self-citationSaugel, B., Scheeren, T. W. L., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1814-y · Cited by 481
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Metadata
- Authors
- Blaivas, M., Brannam, L., & Fernandez, E.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2003-12
- Volume
- 10
- Issue
- 12
- Pages
- 1307-1311
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2007259529
- Cited by
- 161
- References
- 0
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short-axis versus Long-axis Approaches for Teaching Ultrasound-guided Vascular Access on a New Inanimate Model. https://app.cochat.ai/papers/10.1111/j.1553-2712.2003.tb00002.x
- The paper
- Blaivas, M., Brannam, L., & Fernandez, E. (2003). Short-axis versus Long-axis Approaches for Teaching Ultrasound-guided Vascular Access on a New Inanimate Model. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2003.tb00002.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.