A Single Ventilator for Multiple Simulated Patients to Meet Disaster Surge
Open accessThe DOI matches its OpenAlex record.
Abstract
OBJECTIVES: To determine if a ventilator available in an emergency department could quickly be modified to provide ventilation for four adults simultaneously. METHODS: Using lung simulators, readily available plastic tubing, and ventilators (840 Series Ventilator; Puritan-Bennett), human lung simulators were added in parallel until the ventilator was ventilating the equivalent of four adults. Data collected included peak pressure, positive end-expiratory pressure, total tidal volume, and total minute ventilation. Any obvious asymmetry in the delivery of gas to the lung simulators was also documented. The ventilator was run for almost 12 consecutive hours (5.5 hours of pressure control and more than six hours of volume control). RESULTS: Using readily available plastic tubing set up to minimize dead space volume, the four lung simulators were easily ventilated for 12 hours using one ventilator. In pressure control (set at 25 mm H2O), the mean tidal volume was 1,884 mL (approximately 471 mL/lung simulator) with an average minute ventilation of 30.2 L/min (or 7.5 L/min/lung simulator). In volume control (set at 2 L), the mean peak pressure was 28 cm H2O and the minute ventilation was 32.5 L/min total (8.1 L/min/lung simulator). CONCLUSIONS: A single ventilator may be quickly modified to ventilate four simulated adults for a limited time. The volumes delivered in this simulation should be able to sustain four 70-kg individuals. While further study is necessary, this pilot study suggests significant potential for the expanded use of a single ventilator during cases of disaster surge involving multiple casualties with respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
A review of open source ventilators for COVID-19 and future pandemics
Pearce, J. M. (2020) · F1000Research · doi:10.12688/f1000research.22942.1 · Cited by 181
Metadata
- Authors
- Neyman, G., & Irvin, C. B.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2006-08-03
- Volume
- 13
- Issue
- 11
- Pages
- 1246-1249
- ISSN
- 1069-6563 (ISSN-L)
- OpenAlex
- W2051951151
- Cited by
- 183
- References
- 0
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Single Ventilator for Multiple Simulated Patients to Meet Disaster Surge. https://app.cochat.ai/papers/10.1111/j.1553-2712.2006.tb01657.x
- The paper
- Neyman, G., & Irvin, C. B. (2006). A Single Ventilator for Multiple Simulated Patients to Meet Disaster Surge. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2006.tb01657.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.