CoChat

The Diagnostic Value of Ischemia-modified Albumin in a Rat Model of Acute Mesenteric Ischemia: IMA IN MESENTERIC ISCHEMIA

Open access
Uygun, Mecit, Yilmaz, Serkan, Pekdemir, Murat, Duman, Can, Gürbüz, Yeşim Saliha · 2011 · Academic Emergency Medicine
Cited by 26

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Previous studies have demonstrated that ischemia-modified albumin (IMA) is a useful marker for the diagnosis of ischemic events. This study aimed to determine the value of ischemia-modified plasma albumin in the early diagnosis of acute mesenteric ischemia in an experimental model. METHODS: The study was performed on 32 Wistar albino rats divided into control (n = 8), sham (n = 8), 2-hour (n = 8), and 6-hour (n = 8) ischemia groups. Mesenteric ischemia was created by arterial occlusion, and then blood samples (2 mL) were collected and centrifuged. Serum levels of IMA were measured by a rapid calorimetric test that determined the reduced cobalt binding to albumin. For histopathologic evaluation, samples of the small intestine were obtained from the animals after they were euthanized at the end of the experiment. RESULTS: Histopathologic damage of the intestinal wall correlated with the duration of ischemia. While the mean pathology scores of the 2- and 6-hour ischemia groups were different from each other, IMA levels (mean ± SD) in the four groups were not significantly different from each other: 0.55 ± 0.07 absorbance units (ABSU) in the control group, 0.62 ± 0.09 ABSU in the sham group, 0.60 ± 0.07 ABSU in the 2-hour ischemia group, and 0.64 ± 0.12 ABSU in the 6-hour ischemia group (p = 0.153). CONCLUSIONS: Serum IMA values were not useful in the early diagnosis of acute mesenteric ischemia. Further studies to investigate ischemic and nonischemic conditions that affect IMA levels are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1553-2712.2011.01045.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 26

Metadata

Authors
Uygun, M., Yilmaz, S., Pekdemir, M., Duman, C., & Gürbüz, Y. S.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2011-04
Volume
18
Issue
4
Pages
355-359
ISSN
1069-6563 (ISSN-L)
OpenAlex
W1494823024
Cited by
26
References
3
FWCI
3.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Diagnostic Value of Ischemia-modified Albumin in a Rat Model of Acute Mesenteric Ischemia: IMA IN MESENTERIC ISCHEMIA. https://app.cochat.ai/papers/10.1111/j.1553-2712.2011.01045.x
The paper
Uygun, M., Yilmaz, S., Pekdemir, M., Duman, C., & Gürbüz, Y. S. (2011). The Diagnostic Value of Ischemia-modified Albumin in a Rat Model of Acute Mesenteric Ischemia: IMA IN MESENTERIC ISCHEMIA. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2011.01045.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.