Concordance Study Between the AmpFℓSTR® MiniFilerTM PCR Amplification Kit and Conventional STR Typing Kits*
The DOI matches its Crossref record.
Abstract
The AmpFℓSTR® MiniFiler TM polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler® kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler TM Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex‐typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler TM and Identifiler® STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex® 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift. Summary of 27 discordant STR profiling results observed in this study between the Identifiler® and MiniFiler™ kits for 449 different AA, 445 C, 207 H, and 207 A samples.: Locus Ethnicity Source MiniFiler Identifiler PP16 Genetic Variation 1 CSF1PO H IBB 11,11 11, “11.1” 11,11 One base insertion in Identifiler amplicon outside of MiniFiler and PP16 primers 2 D7S820 AA IBB 8,11 8,”9.3” 8,11 5 base deletion in Identifiler amplicon outside of MiniFiler and PP16 primers 3 D13S317 H IBB 11,11 9,11 9,11 4 base deletion in the reverse MiniFiler primer binding region 4 D13S317 H IBB 13,13 9,13 9,13 (same as sample no. 3) 5 D13S317 H IBB 14,14 9,14 9,14 (same as sample no. 3) 6 D13S317 AA IBB 11,11 9,11 9,11 (same as sample no. 3) 7 D13S317 AA IBB 12,12 8,12 8,12 (same as sample no. 3) 8 D13S317 AA IBB 11,11 8,11 8,11 (same as sample no. 3) 9 D13S317 AA IBB 13,13 10,13 10,13 (same as sample no. 3) 10 D13S317 AA IBB 11,11 9,11 9,11 (same as sample no. 3) 11 D13S317 AA IBB 12,12 9,12 9,12 (same as sample no. 3) 12 D13S317 AA DDC 10,10 9,10 13 D13S317 C IBB 12,12 9,12 9,12 (same as sample no. 3) 14 D13S317 C DDC 11,11 10,11 15 D13S317 C DDC 8,8 8,10 16 D13S317 A DDC 12,12 10,12 17 D16S539 AA DDC 9,9 9,11 18 D16S539 AA IBB 12,12 11,12 11,12 A/G SNP in MiniFiler primer binding site 19 D16S539 AA MLN 11,11 9,11 9,11 (same as sample no. 18) 20 D16S539 AA DDC 14,14 11,14 11,14 (same as sample no. 18) 21 D16S539 AA DDC 9,9 9,11 9,11 (same as sample no. 18) 22 D16S539 AA DDC 13,13 11,13 23 D16S539 AA DDC 12,12 11,12 24 D16S539 AA DDC 12,12 11,12 25 D16S539 AA DDC 9,9 9,12 26 D16S539 A ABI 11,11 10,11 G/A SNP in MiniFiler primer binding site 27 D18S51 H IBB 13,15 15,15 13,15 Allele 13 C/T SNP in Identifiler primer binding site Sample sources include IBB, MLN, DDC, and ABI. With only three exceptions (see samples no. 1, 2, 27), PowerPlex® 16 (PP16) results agree with the Identifiler® results for these samples. DNA sequencing was performed to ascertain the genetic variation responsible for the discordance of the impacted allele (shown in bold font). Note that sample no. 15 is the child of sample no. 14, sample no. 20 is the child of sample no. 21, and sample no. 22 is the child of sample no. 23. AA, African American; C, Caucasian; H, Hispanic; A, Asian; MLN, Millennium; IBB, Interstate Blood Bank; DDC, DNA Diagnostic Center; ABI, Applied Biosystems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Short tandem repeat typing technologies used in human identity testing
Butler, J. M. (2007) · BioTechniques · doi:10.2144/000112582 · Cited by 284
Self-citationSTR allele sequence variation: Current knowledge and future issues
Gettings, K. B., Aponte, R. A., Vallone, P. M., & Butler, J. M. (2015) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2015.06.005 · Cited by 205
“[24].”
Self-citationHill, C. R., Duewer, D. L., Kline, M. C., Sprecher, C. J., McLaren, R. S., Rabbach, D. R., Krenke, B. E., Ensenberger, M. G., Fulmer, P. M., Storts, D. R., et al. (2011) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2010.03.014 · Cited by 109
“Lauderdale, FL) and extracted, quantified, and previously typed with the Identifiler kit (Applied Biosystems, Foster City, CA) [18], the PowerPlex 16 (PP16) System (Promega, Madison, WI) (data not published), MiniFiler kit (Applied Biosystems) [19], and the three in-house assays: NIST23plex, -NC01 and -NC02 [20].”
MethodSelf-citation
Metadata
- Authors
- Hill, C. R., Kline, M. C., Mulero, J. J., Lagacé, R. E., Chang, C., Hennessy, L. K., & Butler, J. M.
- Venue
- Journal of Forensic Sciences
- Publisher
- Wiley
- Published
- 2007-06-06
- Volume
- 52
- Issue
- 4
- Pages
- 870-873
- ISSN
- 0022-1198 (ISSN-L)
- 1556-4029
- OpenAlex
- W2047660332
- Cited by
- 83
- References
- 0
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concordance Study Between the AmpFℓSTR® MiniFilerTM PCR Amplification Kit and Conventional STR Typing Kits*. https://app.cochat.ai/papers/10.1111/j.1556-4029.2007.00491.x
- The paper
- Hill, C. R., Kline, M. C., Mulero, J. J., Lagacé, R. E., Chang, C., Hennessy, L. K., & Butler, J. M. (2007). Concordance Study Between the AmpFℓSTR® MiniFilerTM PCR Amplification Kit and Conventional STR Typing Kits*. Journal of Forensic Sciences. https://doi.org/10.1111/j.1556-4029.2007.00491.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.