Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record.

Quality Assessment of Colonoscopic Cecal Intubation: An Analysis of 6 Years of Continuous Practice at a University Hospital

Aslinia, Florence, Uradomo, Lance, Steele, Allison, Greenwald, Bruce D, Raufman, Jean-Pierre · 2006 · The American Journal of Gastroenterology

Abstract

BACKGROUND: Despite increased emphasis on endoscopic performance indicators, e.g., cecal intubation rates, limited data from actual clinical practice have been published. OBJECTIVES: Retrospective database review to determine the rate and documentation of cecal intubation during colonoscopy at the University of Maryland Medical Center. METHODS: We reviewed 5,477 consecutive colonoscopies performed by 10 faculty gastroenterologists at a University hospital over a 6-yr period (March 1, 1999 to February 28, 2005). Unadjusted cecal intubation rates were analyzed as were rates that were adjusted based on the U.S. Multi-Society Task Force on Colorectal Cancer recommendations. We analyzed trends in overall and individual cecal intubation rates, circumstances that impact these rates, and the quality of documentation of cecal intubation. RESULTS: The overall adjusted cecal intubation rate for the entire 6 yr was 90.3%, and increased over the study period with the highest adjusted rate (93.7%) in the most recent year studied. There was no correlation between cecal intubation rate and patient age, gastroenterology fellow involvement, or endoscopist experience and number of procedures/year. In contrast, colon cancer screening, male gender, outpatient colonoscopy, and adequate bowel preparation predicted a higher cecal intubation rate. Written and photographic documentation of cecal intubation improved significantly after 2002. CONCLUSIONS: Our analysis revealed cecal intubation and documentation rates that meet current guidelines, and identified factors that may cause substantial variance in these rates depending on the nature of the practice. The present analysis confirms that computerized databases can be used to assess individual and group cecal intubation and documentation rates on an annual basis, and to make these data available to the public.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1572-0241.2006.00494.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Aslinia, F., Uradomo, L., Steele, A., Greenwald, B. D., & Raufman, J.-P.
Venue
The American Journal of Gastroenterology
Published
2006-04
Volume
101
Issue
4
Pages
721-731
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W2058974064
Cited by
178
References
0
FWCI
6.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality Assessment of Colonoscopic Cecal Intubation: An Analysis of 6 Years of Continuous Practice at a University Hospital. https://app.cochat.ai/papers/10.1111/j.1572-0241.2006.00494.x
The paper
Aslinia, F., Uradomo, L., Steele, A., Greenwald, B. D., & Raufman, J.-P. (2006). Quality Assessment of Colonoscopic Cecal Intubation: An Analysis of 6 Years of Continuous Practice at a University Hospital. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2006.00494.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.