The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
FibroTest and FibroScan for the Prediction of Hepatitis C-Related Fibrosis: A Systematic Review of Diagnostic Test Accuracy
Abstract
BACKGROUND: The accurate diagnosis of hepatitis C virus (HCV)-related fibrosis is crucial for prognostication and treatment decisions. Due to the limitations of biopsy, noninvasive alternatives including FibroTest and FibroScan have been developed. Our objective was to systematically review studies describing the accuracy of these tests for predicting HCV-related fibrosis. METHODS: Studies comparing FibroTest or FibroScan versus biopsy in HCV patients were identified via an electronic search. Random effects meta-analyses and areas under summary receiver operating characteristics curves (AUC) were examined to characterize test accuracy for significant fibrosis (F2-4) and cirrhosis. Heterogeneity was explored using meta-regression. RESULTS: Twelve studies were identified, 9 for FibroTest (N = 1,679) and 4 for FibroScan (N = 546). In heterogeneous analyses for significant fibrosis, the AUCs for FibroTest and FibroScan were 0.81 (95% CI 0.78-84) and 0.83 (0.03-1.00), respectively. At a threshold of approximately 0.60, the sensitivity and specificity of the FibroTest were 47% (35-59%) and 90% (87-92%). For FibroScan (threshold approximately 8 kPa), corresponding values were 64% (50-76%) and 87% (80-91%), respectively. Methodological quality, the length of liver biopsy specimens, and inclusion of special populations did not explain the observed heterogeneity. However, the diagnostic accuracy of both measures was associated with the prevalence of significant fibrosis and cirrhosis in the study populations. For cirrhosis, the summary AUCs for FibroTest and FibroScan were 0.90 (95% CI not calculable) and 0.95 (0.87-0.99), respectively. CONCLUSIONS: FibroTest and FibroScan have excellent utility for the identification of HCV-related cirrhosis, but lesser accuracy for earlier stages. Refinements are necessary before these tests can replace liver biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369 · cited 1×
“These figures are in keeping with those obtained in the bivariate meta-analyses shown in Table 4 (46).”
ResultUsers' guides to the medical literature
Guyatt, G. H. (1993) · JAMA · doi:10.1001/jama.270.17.2096 · Cited by 2,970
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Systematic Reviews in Health Care : Meta-Analysis in Context
Egger, M., Smith, G. D., & Altman, D. G. (2000) · Cited by 2,312
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Lin, Z.-H., Xin, Y.-N., Dong, Q.-J., Wang, Q., Jiang, X.-J., Zhan, S.-H., Sun, Y., & Xuan, S.-Y. (2011) · Hepatology · doi:10.1002/hep.24105 · Cited by 1,067
WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., & on behalf of the Liver Fibrosis Study Group (2012) · Hepatology · doi:10.1002/hep.25936 · Cited by 667
Barr, R. G., Ferraioli, G., Palmeri, M. L., Goodman, Z. D., Garcia-Tsao, G., Rubin, J., Garra, B., Myers, R. P., Wilson, S. R., Rubens, D., et al. (2015) · Radiology · doi:10.1148/radiol.2015150619 · Cited by 632
Self-citation
Metadata
- Authors
- Shaheen, A. A. M., Wan, A. F., & Myers, R. P.
- Venue
- The American Journal of Gastroenterology
- Published
- 2007-11
- Volume
- 102
- Issue
- 11
- Pages
- 2589-2600
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W2072861622
- Cited by
- 360
- References
- 70
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FibroTest and FibroScan for the Prediction of Hepatitis C-Related Fibrosis: A Systematic Review of Diagnostic Test Accuracy. https://app.cochat.ai/papers/10.1111/j.1572-0241.2007.01466.x
- The paper
- Shaheen, A. A. M., Wan, A. F., & Myers, R. P. (2007). FibroTest and FibroScan for the Prediction of Hepatitis C-Related Fibrosis: A Systematic Review of Diagnostic Test Accuracy. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2007.01466.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.