Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 287

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Chromoendoscopy-Targeted Biopsies Are Superior to Standard Colonoscopic Surveillance for Detecting Dysplasia in Inflammatory Bowel Disease Patients: A Prospective Endoscopic Trial

Marion, James F., Waye, Jerome D., Present, Daniel H., Israel, Yuriy, Bodian, Carol, Harpaz, Noam, Chapman, Mark, Itzkowitz, Steven, Steinlauf, Adam F., Abreu, Maria T., Ullman, Thomas A., Aisenberg, James, Mayer, Lloyd, the Chromoendoscopy Study Group at Mount Sinai School of Medicine · 2008 · The American Journal of Gastroenterology

Abstract

OBJECTIVES: Patients with extensive, longstanding chronic ulcerative or Crohn's colitis face greater risks of developing colorectal cancer. Current standard surveillance relies on detecting dysplasia using random sampling at colonoscopy but may fail to detect dysplasia in many patients. Dye spraying techniques have been reported to aid in detecting otherwise subtle mucosal abnormalities in the setting of colitis. We prospectively compared dye-spray technique using methylene blue to standard colonoscopic surveillance in detecting dysplasia. METHODS: One hundred fifteen patients were referred to the Chromoendoscopy Study Group and prospectively screened for the study. One hundred two (64 M, 38 F) (79 UC 23 CC) patients meeting the inclusion criteria were enrolled. Following a standard bowel preparation, each patient was examined using standard office endoscopic equipment by three methods: (a) standard surveillance colonoscopy with four random biopsies every 10 cm (for a total of at least 32 samples); (b) a targeted biopsy protocol; and finally (c) methylene blue (0.01%) dye spray was segmentally applied throughout the colon and any pit-pattern abnormality or lesion rendered visible by the dye spray was targeted and biopsied. Each patient had a single examination, which included two passes of the colonoscope. Specimens were reviewed in a blinded fashion by a single gastrointestinal pathologist. The three methods were then compared with each patient serving as his or her own control. RESULTS: Targeted biopsies with dye spray revealed significantly more dysplasia (16 patients with low grade and 1 patient with high grade) than random biopsies (3 patients with low-grade dysplasia) (P= 0.001) and more than targeted nondye spray (8 patients with low-grade and 1 patient with high-grade dysplasia) (P= 0.057). Targeted biopsies with and without dye spray detected dysplasia in 20 patients compared with 3 using Method (a) (P= 0.0002, two-tailed exact McNemar's Test). There were no adverse events. CONCLUSIONS: Colonoscopic surveillance of chronic colitis patients using methylene blue dye-spray targeted biopsies results in improved dysplasia yield compared to conventional random and targeted biopsy methods. Accordingly, this technique warrants incorporation into clinical practice in this setting and consideration as a standard of care for these patients. The value of multiple random biopsies as a surveillance technique should be revisited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1572-0241.2008.01934.x

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 287

Metadata

Authors
Marion, J. F., Waye, J. D., Present, D. H., Israel, Y., Bodian, C., Harpaz, N., Chapman, M., Itzkowitz, S., Steinlauf, A. F., Abreu, M. T., Ullman, T. A., Aisenberg, J., Mayer, L., & the Chromoendoscopy Study Group at Mount Sinai School of Medicine
Venue
The American Journal of Gastroenterology
Published
2008-09
Volume
103
Issue
9
Pages
2342-2349
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W2043004569
Cited by
287
References
17
FWCI
10.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chromoendoscopy-Targeted Biopsies Are Superior to Standard Colonoscopic Surveillance for Detecting Dysplasia in Inflammatory Bowel Disease Patients: A Prospective Endoscopic Trial. https://app.cochat.ai/papers/10.1111/j.1572-0241.2008.01934.x
The paper
Marion, J. F., Waye, J. D., Present, D. H., Israel, Y., Bodian, C., Harpaz, N., Chapman, M., Itzkowitz, S., Steinlauf, A. F., Abreu, M. T., Ullman, T. A., Aisenberg, J., Mayer, L., & the Chromoendoscopy Study Group at Mount Sinai School of Medicine. (2008). Chromoendoscopy-Targeted Biopsies Are Superior to Standard Colonoscopic Surveillance for Detecting Dysplasia in Inflammatory Bowel Disease Patients: A Prospective Endoscopic Trial. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2008.01934.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.