Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

A Simplified, Noninvasive Stool DNA Test for Colorectal Cancer Detection

Itzkowitz, Steven, Brand, Randall, Jandorf, Lina, Durkee, Kris, Millholland, John, Rabeneck, Linda, Schroy, Paul C., Sontag, Stephen, Johnson, David, Markowitz, Sanford, Paszat, Lawrence, Berger, Barry M. · 2008 · The American Journal of Gastroenterology

Abstract

BACKGROUND: As a noninvasive colorectal cancer (CRC) screening test, a multi-marker first generation stool DNA (sDNA V 1.0) test is superior to guaiac-based fecal occult blood tests. An improved sDNA assay (version 2), utilizing only two markers, hypermethylated vimentin gene (hV) and a two site DNA integrity assay (DY), demonstrated in a training set (phase 1a) an even higher sensitivity (88%) for CRC with a specificity of 82%. AIM: To validate in an independent set of patients (phase 1b) the sensitivity and specificity of sDNA version 2 for CRC. METHODS: Forty-two patients with CRC and 241 subjects with normal colonoscopy (NC) provided stool samples, to which they immediately added DNA stabilizing buffer, and mailed their specimen to the laboratory. DNA was purified using gel-based capture, and analyzed for hV and DY using methods identical to those previously published. RESULTS: Using the same cutpoints as the 1a training set (N = 162; 40 CRCs, 122 normals), hV demonstrated a higher and DY a slightly lower sensitivity, for a combined sensitivity of hV + DY of 86%. Optimal cutpoints based on the combined phase 1a + 1b dataset (N = 445; 82 CRCs, 363 normals) yielded a CRC sensitivity of 83%. The vast majority of cancers were detected regardless of tumor stage, tumor location, or patient age. Assay specificity in the phase 1b dataset for hV, DY, and hV + DY was 82%, 85%, and 73%, respectively, using the phase 1a cutpoints. Optimal cutpoints based on the combined phase 1a + 1b dataset yield a specificity of 82%. CONCLUSIONS: This study provides validation of a simplified, improved sDNA test that incorporates only two markers and that demonstrates high sensitivity (83%) and specificity (82%) for CRC. Test performance is highly reproducible in a large set of patients. The use of only two markers will make the test easier to perform, reduce the cost, and facilitate distribution to local laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1572-0241.2008.02088.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Itzkowitz, S., Brand, R., Jandorf, L., Durkee, K., Millholland, J., Rabeneck, L., Schroy, P. C., Sontag, S., Johnson, D., Markowitz, S., Paszat, L., & Berger, B. M.
Venue
The American Journal of Gastroenterology
Published
2008-11
Volume
103
Issue
11
Pages
2862-2870
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W2069663898
Cited by
161
References
0
FWCI
6.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Simplified, Noninvasive Stool DNA Test for Colorectal Cancer Detection. https://app.cochat.ai/papers/10.1111/j.1572-0241.2008.02088.x
The paper
Itzkowitz, S., Brand, R., Jandorf, L., Durkee, K., Millholland, J., Rabeneck, L., Schroy, P. C., Sontag, S., Johnson, D., Markowitz, S., Paszat, L., & Berger, B. M. (2008). A Simplified, Noninvasive Stool DNA Test for Colorectal Cancer Detection. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2008.02088.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.