Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record.

Clinical evaluation of an Er:YAG laser for nonsurgical treatment of peri‐implantitis: a pilot study

Schwarz, Frank, Sculean, Anton, Rothamel, Daniel, Schwenzer, Katja, Georg, Thomas, Becker, Jürgen·2005·Clinical Oral Implants Research

Abstract

Abstract: The aim of this controlled, parallel design clinical study was to compare the effectiveness of an Er:YAG laser (ERL) to that of mechanical debridement using plastic curettes and antiseptic therapy for nonsurgical treatment of peri‐implantitis. Twenty patients with moderate to advanced peri‐implantitis lesions were randomly treated with either (1) an ERL using a cone‐shaped glass fiber tip at an energy setting of 100 mJ/pulse and 10 pps (ERL), or (2) mechanical debridement using plastic curettes and antiseptic therapy with chlorhexidine digluconate (0.2%) (C). The following clinical parameters were measured at baseline, 3 and 6 months after treatment by one blinded and calibrated examiner: Plaque index (PI), bleeding on probing (BOP), probing depth (PD), gingival recession (GR) and clinical attachment level (CAL). At the baseline examination, there were no statistically significant differences in any of the investigated parameters. Mean value of BOP decreased in the ERL group from 83% at baseline to 31% after 6 months (P<0.001) and in the C group from 80% at baseline to 58% after 6 months (P<0.001). The difference between the two groups was statistically significant (P<0.001, respectively). The sites treated with ERL demonstrated a mean CAL change from 5.8±1 mm at baseline to 5.1±1.1 mm (P<0.01) after 6 months. The C sites demonstrated a mean CAL change from 6.2±1.5 mm at baseline to 5.6±1.6 mm (P<0.001) after 6 months. After 6 months, the difference between the two groups was statistically not significant (P>0.05). Within the limits of the present study, it was concluded that (i) at 6 months following treatment both therapies led to significant improvements of the investigated clinical parameters, and (ii) ERL resulted in a statistically significant higher reduction of BOP than C.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2004.01051.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Schwarz, F., Sculean, A., Rothamel, D., Schwenzer, K., Georg, T., & Becker, J.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2004-07-14
Volume
16
Issue
1
Pages
44-52
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1733418913
Cited by
226
References
0
FWCI
6.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical evaluation of an Er:YAG laser for nonsurgical treatment of peri‐implantitis: a pilot study. https://app.cochat.ai/papers/10.1111/j.1600-0501.2004.01051.x
The paper
Schwarz, F., Sculean, A., Rothamel, D., Schwenzer, K., Georg, T., & Becker, J. (2005). Clinical evaluation of an Er:YAG laser for nonsurgical treatment of peri‐implantitis: a pilot study. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2004.01051.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.