The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Peri‐implant soft‐tissue health surrounding cement‐ and screw‐retained implant restorations: a multi‐center, 3‐year prospective study
Abstract
Objective: The purpose of this prospective clinical study was to evaluate peri‐implant soft‐tissue conditions and esthetic fulfillment during a 3‐year follow‐up period following prosthetic rehabilitation. Material and methods: As part of a prospective multi‐center study, 152 ITI dental implants were placed in 80 patients in the maxillary anterior region. Fifty‐nine crowns (38.82%) were cement retained, while 93 (61.18%) crowns were screw retained. At loading and 3, 6, 12 and 36 months post‐loading, modified plaque index (MPI), sulcus bleeding index (SBI), keratinized mucosa (KM), gingival level (GL), and esthetic fulfillment were recorded. Results: All patients completed the study and no complications were reported. While statistically not significant at all time points, cement‐retained crowns seemed to present a worsening trend in MPI and SBI scores. Interestingly, screw‐retained crowns seemed to present an opposite picture, their MPI and SBI scores improved over time. While plaque accumulation, prophylaxis and depth of crown margin significantly affected levels of sulcus bleeding, prophylaxis alone played a key role in reducing plaque accumulation. No soft tissue recession was observed in either cement‐ or screw‐retained crowns up to 3 years post‐loading. Esthetic fulfillment survey revealed that patients did not have a preference for crown types; however, dentists favored cement‐retained over screw‐retained crowns. Conclusions: Peri‐implant soft tissues responded more favorably to screw‐retained crowns when compared with cement‐retained crowns. However, no soft‐tissue recession was observed in either type of crowns. Cement‐retained crowns were preferred by dentists, while patients were equally satisfied with either type of crowns they received.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buser, D., Weber, H. ‐., & Lang, N. P. (1990) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1990.010105.x · Cited by 724
Self-citationLang, N. P., Kiel, R. A., & Anderhalden, K. (1983) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1983.tb01295.x · Cited by 399
Effect of Rough Surfaces Upon Gingival Tissue
Waerhaug, J. (1956) · Journal of Dental Research · doi:10.1177/00220345560350022601 · Cited by 243
Cited by
Sailer, I., Mühlemann, S., Zwahlen, M., Hämmerle, C. H. F., & Schneider, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02538.x · Cited by 480
Sailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368
Metadata
- Authors
- Weber, H. P., Kim, D. M., Ng, M. W., Hwang, J. W., & Fiorellini, J. P.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2006-06-06
- Volume
- 17
- Issue
- 4
- Pages
- 375-379
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1985794873
- Cited by
- 158
- References
- 3
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.