Analysis of intensity variability in multislice and cone beam computed tomography: Intensity variability in MSCT and CBCT
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objectives: The aim of this study was to evaluate the variability of intensity values in cone beam computed tomography (CBCT) imaging compared with multislice computed tomography Hounsfield units (MSCT HU) in order to assess the reliability of density assessments using CBCT images. Material and methods: A quality control phantom was scanned with an MSCT scanner and five CBCT scanners. In one CBCT scanner, the phantom was scanned repeatedly in the same and in different positions. Images were analyzed using registration to a mathematical model. MSCT images were used as a reference. Results: Density profiles of MSCT showed stable HU values, whereas in CBCT imaging the intensity values were variable over the profile. Repositioning of the phantom resulted in large fluctuations in intensity values. Conclusions: The use of intensity values in CBCT images is not reliable, because the values are influenced by device, imaging parameters and positioning. To cite this article: Nackaerts O, Maes F, Yan H, Couto Souza P, Pauwels R, Jacobs R. Analysis of intensity variability in multislice and cone beam computed tomography.Clin. Oral Impl. Res. 22, 2011; 873–879.doi: 10.1111/j.1600-0501.2010.02076.x
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationOral radiology. Principles and interpretation
Seward, G. R. (1983) · Journal of Dentistry · doi:10.1016/0300-5712(83)90209-9 · Cited by 1,547
Clinical applications of cone-beam computed tomography in dental practice.
Scarfe, W. C., Farman, A. G., & Sukovic, P. (2006) · PubMed · Cited by 1,528
Quantitative CT for determination of bone mineral density: a review.
Cann, C. E. (1988) · Radiology · doi:10.1148/radiology.166.2.3275985 · Cited by 354
Quantitative evaluation of bone density using the Hounsfield index.
Shapurian, T., Damoulis, P. D., Reiser, G. M., et al. (2006) · PubMed · Cited by 296
Comparison of radiation levels from computed tomography and conventional dental radiographs
Ngan, D. C. S., Kharbanda, O. P., Geenty, J. P., & Darendeliler, M. A. (2003) · Australasian Orthodontic Journal · doi:10.2478/aoj-2003-0009 · Cited by 186
Assessments of trabecular bone density at implant sites on CT images
de Oliveira, R. C. G., Leles, C. R., Normanha, L. M., Lindh, C., & Ribeiro‐Rotta, R. F. (2008) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2007.08.007 · Cited by 157
A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup
Rinkel, J., Gerfault, L., Estève, F., & Dinten, J. ‐. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/018 · Cited by 129
Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system
Bryant, J. A., Drage, N. A., & Richmond, S. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/13227258 · Cited by 112
Lecomber, A. R., Yoneyama, Y., Lovelock, D. J., HOSOI, T., & Adams, A. (2001) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600627 · Cited by 104
DEXA as a Predictor of Fixator Removal in Distraction Osteogenesis
Saran, N., & Hamdy, R. C. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0514-y · Cited by 52
Osteoporosis detection using intraoral densitometry
Nackaerts, O., Jacobs, R., Devlin, H., et al. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30424604 · Cited by 52
Self-citation
Cited by
Bornstein, M., Scarfe, W., Vaughn, V., & Jacobs, R. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g1.4 · Cited by 361
Self-citationMaxillofacial cone beam computed tomography: essence, elements and steps to interpretation
Scarfe, W., Li, Z., Aboelmaaty, W., Scott, S., & Farman, A. (2012) · Australian Dental Journal · doi:10.1111/j.1834-7819.2011.01657.x · Cited by 232
“In addition, greyscale intensity values measured on CBCT images do not directly represent Hounsfield units (HU), the relative density of body tissues according to a calibrated grey-level scale, based on normalized-HU values for air ()1000 HU), water (0 HU), and dense bone (+1000 HU).(26,27) While these conditions limi…”
Background
Metadata
- Authors
- Nackaerts, O., Maes, F., Yan, H., Couto Souza, P., Pauwels, R., & Jacobs, R.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-01-18
- Volume
- 22
- Issue
- 8
- Pages
- 873-879
- ISSN
- 0905-7161 (ISSN-L)
- OpenAlex
- W1961938883
- Cited by
- 192
- References
- 12
- FWCI
- 17.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.