Stability of cp‐Ti and Ti‐6 Al‐4 V alloy for dental implants as a function of saliva pH – an electrochemical study
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objectives: To investigate the role of different levels of pH of artificial saliva under simulated oral environment on the corrosion behavior of commercially pure titanium (cp‐Ti) and Ti‐6 Al‐4 V alloy. Special attention is given to understand the changes in corrosion kinetics and surface characterization of Ti by using electrochemical impedance spectroscopy (EIS). Materials and methods: Fifty‐four Ti disks (15‐mm diameter, 2‐mm thickness) were divided into six groups (n = 9) as a function of saliva pH (3, 6.5, and 9) and Ti type. Samples were mechanically polished using standard metallographic procedures. Standard electrochemical tests, such as open circuit potential, EIS, and potentiodynamic tests were conducted in a controlled environment. Data were evaluated by two‐way ANOVA, T ukey multiple comparison test, and independent t‐test (α = 0.05). Ti surfaces were examined using white‐light‐interferometry microscopy and scanning electron microscopy (SEM). Results: Saliva pH level significantly affected the corrosion behavior of both Ti types. At low pH, acceleration of ions exchange between Ti and saliva, and reduction of resistance of Ti surface against corrosion were observed (P < 0.05). Corrosion rate was also significantly increased in acidic medium (P < 0.05). Similar corrosion behavior was observed for both Ti types. The white‐light‐interferometry images of Ti surfaces show higher surface changes at low pH level. SEM images do not show detectable changes. No pitting corrosion was observed for any group. Conclusions: The pH level of artificial saliva influences the corrosion behavior of cp‐Ti and Ti‐6 Al‐4 V alloy in that lower pH accelerates the corrosion rate and kinetics. The corrosion products may mitigate the survival rate of dental implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070302.x · Cited by 661 · cited 1×
“In dentistry, roughness is an important property of adhesion and colonization of bacteria (Morgan & Wilson 2001); therefore, a greater biofilm accumulation may be expected on the Ti surface after corrosion mainly at pH 3, which may lead to peri-implantitis (Bollen et al. 1996).”
BackgroundInfluence of fluoride content and pH on the corrosion resistance of titanium and its alloys
Schiff, N., Grosgogeat, B., Lissac, M., & Dalard, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00328-3 · Cited by 428 · cited 4×
“Similar results were observed by Schiff et al. (2002) who compared the corrosion resistance of NiTi, NiTiCo, and Ti-6Al-4V alloys with cp-Ti in Fusayama Meyer artificial saliva at pHs 2.5 and 5.3.”
BackgroundResultInfluentialAn overview of the corrosion aspect of dental implants (titanium and its alloys)
Chaturvedi, T. P. (2009) · Indian Journal of Dental Research · doi:10.4103/0970-9290.49068 · Cited by 297 · cited 4×
“edema, stomatitis, gingivitis), and eczematous rashes (Chaturvedi 2009).”
BackgroundInfluentialComparative corrosion study of Ti–Ta alloys for dental applications
Mareci, D., Chelariu, R., Gordin, D.-M., Ungureanu, G., & Gloriant, T. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.037 · Cited by 230 · cited 4×
“Recent studies have evaluated the effects of acidic pH of electrolyte solution on Ti corrosive behavior (Mereci et al. 2009; Souza et al. 2009).”
BackgroundInfluentialMorgan, T. D., & Wilson, M. (2001) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2001.01338.x · Cited by 210 · cited 1×
“In dentistry, roughness is an important property of adhesion and colonization of bacteria (Morgan & Wilson 2001); therefore, a greater biofilm accumulation may be expected on the Ti surface after corrosion mainly at pH 3, which may lead to peri-implantitis (Bollen et al. 1996).”
BackgroundDo oral biofilms influence the wear and corrosion behavior of titanium?
Souza, J. C. M., Henriques, M., de Oliveira, R. P. S., Teughels, W., Célis, J., & Rocha, L. A. (2010) · Biofouling · doi:10.1080/08927011003767985 · Cited by 149 · cited 1×
“…(Nakagawa et al. 1999; Schiff et al. 2002; Huang 2003; Correa et al. 2009; Mereci et al. 2009), albumin (Huang 2003), bacteria (Laurent et al. 2001; Souza et al. 2010), inflammatory and hyperglycemic conditions (Lin & Bumgardner 2004; Messer et al. 2009, 2010) and lipopolysaccharide (Barão et al.…”
BackgroundMabboux, F., Ponsonnet, L., Morrier, J.-J., Jaffrezic-Renault, N. J., & Barsotti, O. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.08.002 · Cited by 144 · cited 1×
“Commercially pure titanium (cp-Ti) and Ti alloys (such as Ti-6Al-4V) have been widely used to fabricate dental implants due to their resistance to corrosion and biocompatibility (Cortada et al. 2000; Schiff et al. 2002; Mabboux et al. 2004; Vieira et al. 2006).”
BackgroundThe Role of Lipopolysaccharide on the Electrochemical Behavior of Titanium
Barão, V. A. R., Mathew, M. T., Assunção, W. G., Yuan, J. C., Wimmer, M. A., & Sukotjo, C. (2011) · Journal of Dental Research · doi:10.1177/0022034510396880 · Cited by 97 · cited 1×
“…et al. 1999; Schiff et al. 2002; Huang 2003; Correa et al. 2009; Mereci et al. 2009), albumin (Huang 2003), bacteria (Laurent et al. 2001; Souza et al. 2010), inflammatory and hyperglycemic conditions (Lin & Bumgardner 2004; Messer et al. 2009, 2010) and lipopolysaccharide (Barão et al. 2011).”
BackgroundSelf-citationComparison of corrosion behaviour in presence of oral bacteria
Laurent, F., Grosgogeat, B., Reclaru, L., Dalard, F., & Lissac, M. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00416-6 · Cited by 71 · cited 2×
“…presence of fluoride (Nakagawa et al. 1999; Schiff et al. 2002; Huang 2003; Correa et al. 2009; Mereci et al. 2009), albumin (Huang 2003), bacteria (Laurent et al. 2001; Souza et al. 2010), inflammatory and hyperglycemic conditions (Lin & Bumgardner 2004; Messer et al. 2009, 2010) and…”
BackgroundNikolopoulou, F. (2006) · Implant Dentistry · doi:10.1097/01.id.0000239320.57403.8d · Cited by 65 · cited 8×
“…drinks and juices – pH around 2.5-3.5), mouthwash products (Dong et al. 1999; Gregory-Head et al. 2000; Murrell et al. 2010), smoking, chronic/systemic diseases and medication, which may also contribute to the corrosion of dental implants (Nikolopoulou 2006; Vieira et al. 2006; Correa et al. 2009).”
BackgroundInfluential
Cited by
Mombelli, A., Hashim, D., & Cionca, N. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13305 · Cited by 213
Costa, R. C., Souza, J. G. S., Bertolini, M., Retamal‐Valdes, B., Feres, M., & Barão, V. A. R. (2020) · Clinical Oral Implants Research · doi:10.1111/clr.13663 · Cited by 48
Self-citation
Metadata
- Authors
- Barão, V. A. R., Mathew, M. T., Assunção, W. G., Yuan, J. C., Wimmer, M. A., & Sukotjo, C.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-08
- Volume
- 23
- Issue
- 9
- Pages
- 1055-1062
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2004698741
- Cited by
- 161
- References
- 10
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.