CoChat

Surface‐free energy and bacterial adhesion: An in vivo study in beagle dogs

van Dijk, Johan, Herkströter, Frank, Busscher, Henk, Weerkamp, Anton, Jansen, Henk, Arends, Joop · 1987 · Journal of Clinical Periodontology
Cited by 116

The DOI matches its Crossref record.

Abstract

Abstract Conflicting reports have been presented on the rôle of substratum surface free energy (s.f.e.) on bacterial adherence. It is the aim of the present study to evaluate the effect of the s.f.e. of substrata on bacterial adherence in vivo. The following substrata with s.f.e. varying from 23.3.–124.9 erg·cm−2 were cut into facings of 5 by 6 mm. polished and cleaned: polytetrafluorethylene (PTFE). Parafilm. polyvinylchloride (PVC). polymethylmethacrylate (PMMA), bovine dentin, bovine enamel and glass. In 5 beagle dogs, 7–9 years old. part of the buccal periodontium of the upper cuspids was excised and crowns were made and cemented with a non‐fluoridated cement. The facings were placed in the crowns and placed in the oral cavity for 2 h. After removal, the facings were rinsed in saline. S.f.e. was assessed from contact angles with water, water/n‐propanol mixtures and a‐bromonaphthalene. according to the concept of dispersion and polar components, firstly on clean air dried facings and later on facings exposed to the oral cavity for 2 h. Immediately after rinsing, the water contact angle was measured as a function of time, to monitor the evaporation of free water from the protein layer adsorbed on the substrata which had been exposed to the oral cavity. It appeared that after a rapid increase in contact angle, a stable maximum value was obtained after 40–120 min depending on the substratum. S.f.e.'s of the protein‐coated substrata were subsequently determined after a 120 min drying period. Following the contact angle determinations, the exposed facings were stained with ethidram bromide, enabling fluorescence microscopical counting of the adhered microorganisms. The oral environment markedly changed the substratum s.f.e.'s. Salivary protein adsorption reduced differences originally present in s.f.e. Low values increased, while high values decreased, yielding an average value of about 80 erg·cm−2. More micro‐organisms adhered to substrata with an initially high s.f.e. than to substrata with an initially low s.f.e. (PTFE and Parafilm). The highest number of micro‐organisms adhered to PVC (60·10 4 cm−2), the lowest to Parafilm (60·10 4 cm−2). It is interesting to note, that this relation was obtained, despite the fact that surfaces in the oral cavity are almost immediately covered with an adsorbed protein layer, shielding the physicochemical characteristics of the underlying substrata.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-051x.1987.tb01537.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 116

Metadata

Authors
van Dijk, J., Herkströter, F., Busscher, H., Weerkamp, A., Jansen, H., & Arends, J.
Venue
Journal of Clinical Periodontology
Publisher
Wiley
Published
1987-05
Volume
14
Issue
5
Pages
300-304
ISSN
  • 0303-6979 (ISSN-L)
  • 1600-051X
OpenAlex
W1929083789
Cited by
116
References
0
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface‐free energy and bacterial adhesion: An in vivo study in beagle dogs. https://app.cochat.ai/papers/10.1111/j.1600-051x.1987.tb01537.x
The paper
van Dijk, J., Herkströter, F., Busscher, H., Weerkamp, A., Jansen, H., & Arends, J. (1987). Surface‐free energy and bacterial adhesion: An in vivo study in beagle dogs. Journal of Clinical Periodontology. https://doi.org/10.1111/j.1600-051x.1987.tb01537.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.