The DOI matches its Crossref record.
Spectral fluorescence lifetime detection and selective melanin imaging by multiphoton laser tomography for melanoma diagnosis
Abstract
Abstract: Multiphoton excited tissue fluorescence summarises the emission of all naturally occurring endogenous fluorescent bio‐molecules with their often overlapping fluorescence spectra. Common fluorescence intensity measurements could not be utilised to distinguish between different fluorophores or metabolic states. To overcome this limitation, we investigated new procedures of selective melanin imaging and spectral fluorescence lifetime imaging in combination with high resolution multiphoton laser tomography. Overall 46 melanocytic lesions of human skin were analysed. We suggested that fluorescence light, detected in such a way, may yield additional information for melanoma diagnostics. Remarkable differences in lifetime behaviour of keratinocytes in contrast to melanocytes were observed. Fluorescence lifetime distribution was found in correlation with the intracellular amount of melanin. Spectral analysis of melanoma revealed a main fluorescence peak around 470 nm in combination with an additional peak close to 550 nm throughout all epidermal layers. Excitation at 800 nm shows a selectively observable fluorescence of melanin containing cells and offers the possibility of cell classification. Procedures of selective imaging as well as spectral fluorescence lifetime imaging by means of multiphoton laser tomography support diagnostic decisions and may improve the process of non‐invasive early detection of melanoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Yakimov, B. P., Shirshin, E. A., Schleusener, J., Allenova, A. S., Fadeev, V. V., & Darvin, M. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-71220-6 · Cited by 56
Metadata
- Authors
- Dimitrow, E., Riemann, I., Ehlers, A., Koehler, M. J., Norgauer, J., Elsner, P., König, K., & Kaatz, M.
- Venue
- Experimental Dermatology
- Publisher
- Wiley
- Published
- 2009-05-20
- Volume
- 18
- Issue
- 6
- Pages
- 509-515
- ISSN
- 0906-6705 (ISSN-L)
- 1600-0625
- OpenAlex
- W2004068658
- Cited by
- 174
- References
- 0
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral fluorescence lifetime detection and selective melanin imaging by multiphoton laser tomography for melanoma diagnosis. https://app.cochat.ai/papers/10.1111/j.1600-0625.2008.00815.x
- The paper
- Dimitrow, E., Riemann, I., Ehlers, A., Koehler, M. J., Norgauer, J., Elsner, P., König, K., & Kaatz, M. (2009). Spectral fluorescence lifetime detection and selective melanin imaging by multiphoton laser tomography for melanoma diagnosis. Experimental Dermatology. https://doi.org/10.1111/j.1600-0625.2008.00815.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.