This publication summarizes field investigations and controlled experiments on the relation between low levels of indoor air pollution with volatile organic compounds (VOC) and human health and comfort. The Henle-Kock criteria from epidemiology are revised for the dose-response relation between VOC's and health as comfort effects and existing evidence for each criterion are discussed. A biological model for human responses is suggested, based on three mechanisms: sensory perception of the environment, weak inflammatory reactions, and environmental stress reactions. Further, the TVOC-indicator concept for exposure is discussed. The conclusion is that no experimental or field data contradict the proposed causality. On the contrary, evidence supports the suggested causality. The biological model, however, is not yet based on acceptable measures of the variables for exposures, co-variables or health effects. A tentative guideline for VOC's in non-industrial indoor environments is suggested. The no-effect level seems to be about 0.2 mg/m3. A multi-factorial exposure range may exist between 0.2 and 3 mg/m3. Above 3 mg/m3 discomfort is expected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Causation and disease: the Henle-Koch postulates revisited.
Evans, A. S. (1976) · PubMed Central · Cited by 644
The use of chemical potentials as indices of toxicity
Ferguson, J. (1939) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1939.0030 · Cited by 558
Human reactions to low concentrations of volatile organic compounds
Mølhave, L., Bach, B., & Pedersen, O. F. (1986) · Environment International · doi:10.1016/0160-4120(86)90027-9 · Cited by 441
Air pollution sources in offices and assembly halls, quantified by the olf unit
Fanger, P. O., Lauridsen, J., Bluyssen, P., & Clausen, G. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90052-7 · Cited by 168
Thermodynamic analysis of the relative effectiveness of narcotics
Brink, F., & Posternak, J. M. (1948) · Journal of Cellular and Comparative Physiology · doi:10.1002/jcp.1030320208 · Cited by 132
Lung Function and Bronchial Reactivity in Asthmatics during Exposure to Volatile Organic Compounds
Harving, H., Dahl, R., & Mølhave, L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.4_pt_1.751 · Cited by 106
Temporal integration of pungency
Cometto‐Muñiz, J. E., & Cain, W. S. (1984) · Chemical Senses · doi:10.1093/chemse/8.4.315 · Cited by 91
Subjective reactions to volatile organic compounds as air pollutants
Mølhave, L., Grønkjær, J., & Larsen, S. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90240-8 · Cited by 80
Volatile organic compounds in dutch homes
Lebret, E., van de Wiel, H. J., Hp, B., Noij, D., & Boleij, J. S. M. (1986) · Environment International · doi:10.1016/0160-4120(86)90046-2 · Cited by 71
Activation of the sensory irritant receptor by C7?C11 n-alkanes
Kristiansen, U., & Nielsen, G. D. (1988) · Archives of Toxicology · doi:10.1007/bf00293686 · Cited by 38
The effect of ventilation and air pollution on perceived indoor air quality in five town halls
Zweers, T., Skov, P., Valbjørn, O., & Mølhave, L. (1990) · Energy and Buildings · doi:10.1016/0378-7788(90)90038-k · Cited by 25
Cited by
Organic–Inorganic Hybrid Nanocomposite-Based Gas Sensors for Environmental Monitoring
Kaushik, A., Kumar, R., Arya, S. K., Nair, M., Malhotra, B. D., & Bhansali, S. (2015) · Chemical Reviews · doi:10.1021/cr400659h · Cited by 534
Risk assessment of exposure to volatile organic compounds in different indoor environments
Guo, H., Lee, S. C., Chan, L. Y., & Li, W. M. (2004) · Environmental Research · doi:10.1016/s0013-9351(03)00035-5 · Cited by 529
A review of the emission of VOCs from polymeric materials used in buildings
Yu, C., & Crump, D. (1998) · Building and Environment · doi:10.1016/s0360-1323(97)00055-3 · Cited by 352
Total Volatile Organic Compounds (TVOC) in Indoor Air Quality Investigations*
Molhave, L., Clausen, G., Berglund, B., Ceaurriz, J., Kettrup, A., Lindvall, T., Maroni, M., Pickering, A. C., Risse, U., Rothweiler, H., et al. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.00002.x · Cited by 314
Self-citationNon-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Metadata
- Authors
- Molhave, L.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1991-12
- Volume
- 1
- Issue
- 4
- Pages
- 357-376
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2092344233
- Cited by
- 315
- References
- 11
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.