Ozone in Residential Air: Concentrations, I/O Ratios, Indoor Chemistry, and Exposures
The DOI matches its Crossref record.
Abstract
Ozone concentrations were measured in indoor and outdoor residential air during the summer of 1992. Six homes located in a New Jersey suburban area were chosen for analysis, and each home was monitored for 6 days under different ventilation and indoor combustion conditions. The 5-hour average ozone concentration outdoors over the monitoring period was 95 ± 36 ppbv. One third of the days exceeded the National Ambient Air Quality Standard (NAAQS), one-hour maximum concentration of 120 ppb. The mean indoor to outdoor (I/O) ratios of ozone concentration ranged from 0.22 ± 0.09 to 0.62 ± 0.11, depending upon ventilation rate and indoor gas combustion. The presence of indoor gas combustion can significantly decrease the I/O ratio. Because of the great amount of time that people spend indoors, the indoor residential exposures were estimated to account for 57% of the total residential exposures. One type of the possible gas-phase reactions for indoor ozone, the reaction of ozone with a volatile organic compound containing unsaturated carbon-carbon bonds, is discussed with some supporting evidence provided in the study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Ozone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Uhde, E., & Salthammer, T. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.082 · Cited by 347
Total Volatile Organic Compounds (TVOC) in Indoor Air Quality Investigations*
Molhave, L., Clausen, G., Berglund, B., Ceaurriz, J., Kettrup, A., Lindvall, T., Maroni, M., Pickering, A. C., Risse, U., Rothweiler, H., et al. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.00002.x · Cited by 314
Metadata
- Authors
- Zhang, J., & Lioy, P. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1994-06
- Volume
- 4
- Issue
- 2
- Pages
- 95-105
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W1975772859
- Cited by
- 81
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ozone in Residential Air: Concentrations, I/O Ratios, Indoor Chemistry, and Exposures. https://app.cochat.ai/papers/10.1111/j.1600-0668.1994.t01-2-00004.x
- The paper
- Zhang, J., & Lioy, P. J. (1994). Ozone in Residential Air: Concentrations, I/O Ratios, Indoor Chemistry, and Exposures. Indoor Air. https://doi.org/10.1111/j.1600-0668.1994.t01-2-00004.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.