The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Personalized ventilation
Abstract
UNLABELLED: The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard to physiological and psychological response, clothing insulation, activity, air temperature and air movement preference, etc. Environmental conditions acceptable for most occupants in rooms may be achieved by providing each occupant with the possibility to generate and control his/her own preferred microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice. Performance criteria are defined. Recommendations for design of PV that would be in compliance with the criteria are given. Future research needed on the topic is outlined. PRACTICAL IMPLICATIONS: Personalized ventilation can improve occupants' comfort, decrease SBS symptoms and reduce the risk of transmission of contagion between occupants in comparison with total volume ventilation. However in order to perform efficiently in rooms in practice, the design (air distribution, control, etc.) has to be carefully considered together with type of occupant activity (occupancy rate, occupied density, etc.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Airborne Transmission of Communicable Infection — The Elusive Pathway
Roy, C. J., & Milton, D. K. (2004) · New England Journal of Medicine · doi:10.1056/nejmp048051 · Cited by 342
Personalized ventilation: evaluation of different air terminal devices
Melikov, A. K., Cermak, R., & Majer, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00102-0 · Cited by 332
Self-citationPersonal Exposure in Displacement Ventilated Rooms
Brohus, H., & Nielsen, P. V. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-1-00003.x · Cited by 157
Melikov, A. K., Pichurov, G., Naydenov, K. G., & Langkilde, G. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00337.x · Cited by 153
Self-citationVentilation for buildings. Design criteria for the indoor environment
(1999) · BSI Standards · doi:10.3403/01739104 · Cited by 83
Ambient temperatures preferred by young European males and females at rest
GRIVEL, F., & CANDAS, V. (1991) · Ergonomics · doi:10.1080/00140139108967320 · Cited by 75
Testing of Localized Ventilation Systems in a New Controlled Environment Chamber
Arens, E. A., Bauman, F. S., Johnston, L., & Zhang, H. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.05-13.x · Cited by 60
Cited by
Emerging Materials and Strategies for Personal Thermal Management
Hu, R., Liu, Y., Shin, S., Huang, S., Ren, X., Shu, W., Cheng, J., Tao, G., Xu, W., Chen, R., et al. (2020) · Advanced Energy Materials · doi:10.1002/aenm.201903921 · Cited by 638
A review of the performance of different ventilation and airflow distribution systems in buildings
Cao, G., Awbi, H., Yao, R., Fan, Y., Sirén, K., Kosonen, R., & Zhang, J. (. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.12.009 · Cited by 525
Short-range airborne route dominates exposure of respiratory infection during close contact
Chen, W., Zhang, N., Wei, J., Yen, H.-L., & Li, Y. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106859 · Cited by 371
Personalized conditioning and its impact on thermal comfort and energy performance – A review
Veselý, M., & Zeiler, W. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.024 · Cited by 322
Nazaroff, W. W. (2016) · Indoor Air · doi:10.1111/ina.12174 · Cited by 304
Metadata
- Authors
- Melikov, A. K.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2004-08
- Volume
- 14
- Issue
- s7
- Pages
- 157-167
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W4239949177
- Cited by
- 399
- References
- 13
- FWCI
- 18.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Personalized ventilation. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00284.x
- The paper
- Melikov, A. K. (2004). Personalized ventilation. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00284.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.