Personalized ventilation

Melikov, A. K.·2004·Indoor Air

Abstract

UNLABELLED: The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard to physiological and psychological response, clothing insulation, activity, air temperature and air movement preference, etc. Environmental conditions acceptable for most occupants in rooms may be achieved by providing each occupant with the possibility to generate and control his/her own preferred microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice. Performance criteria are defined. Recommendations for design of PV that would be in compliance with the criteria are given. Future research needed on the topic is outlined. PRACTICAL IMPLICATIONS: Personalized ventilation can improve occupants' comfort, decrease SBS symptoms and reduce the risk of transmission of contagion between occupants in comparison with total volume ventilation. However in order to perform efficiently in rooms in practice, the design (air distribution, control, etc.) has to be carefully considered together with type of occupant activity (occupancy rate, occupied density, etc.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2004.00284.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 399

Metadata

Authors
Melikov, A. K.
Venue
Indoor Air
Published
2004-08
Volume
14
Issue
s7
Pages
157-167
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W4239949177
Cited by
399
References
13
FWCI
18.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Personalized ventilation. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00284.x
The paper
Melikov, A. K. (2004). Personalized ventilation. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00284.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.