Impact of dynamic airflow on human thermal response
The DOI matches its Crossref record.
Abstract
UNLABELLED: Airflow fluctuation is an important factor affecting indoor thermal environments and human thermal response. In this study, dynamic airflows with different fluctuation characteristics were generated by a dynamic air supply terminal. The influence of three different kinds of airflows, constant airflow, simulated natural airflow and sinusoidal airflow, on thermal comfort was studied. Subjective experiments indicated that a dynamic airflow can cause a stronger cold sensation, and that air movement with 1/f fluctuations similar to natural wind is more acceptable than other dynamic airflows in warm environments. Moreover, the impact of draughts in dynamic airflows on human thermal response is different in neutral-warm (30 degrees C) and cool-neutral (26 degrees C) thermal environments. PRACTICAL IMPLICATIONS: By means of a dynamic air supply terminal it is possible to generate artificial airflows that simulate natural wind indoors. This kind of airflow with higher velocity is more comfortable and causes less draught sensation than the constant airflows supplied by conventional fans. While the cooling effect of this airflow is utilized in the built environment, the design temperature of air-conditioning system can be increased and the amount of energy consumption can be reduced dramatically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
“simulated natural wind [145] and with different airflow fluctuation frequencies [146,147] in thermal comfort.”
BackgroundProgress in thermal comfort research over the last twenty years
de Dear, R. J., Akimoto, T., Arens, E. A., Brager, G., Candido, C., Cheong, K. W. D., Li, B., Nishihara, N., Sekhar, S. C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 523
Self-citationRevisiting an old hypothesis of human thermal perception: alliesthesia
de Dear, R. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552269 · Cited by 333
Thermal pleasure in built environments: physiology of alliesthesia
Parkinson, T., & de Dear, R. (2015) · Building Research & Information · doi:10.1080/09613218.2015.989662 · Cited by 263
“More recent research including both laboratory studies (e.g. Tanabe & Kimura, 1994; Zhou et al., 2006) and field research (e.”
BackgroundMethodA review of different ventilation modes on thermal comfort, air quality and virus spread control
Fan, M., Fu, Z., Wang, J., Wang, Z., Suo, H., Kong, X., & Li, H. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108831 · Cited by 168
Metadata
- Authors
- Zhou, X., Ouyang, Q., Lin, G., & Zhu, Y.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2006-10
- Volume
- 16
- Issue
- 5
- Pages
- 348-355
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W1966622730
- Cited by
- 100
- References
- 0
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of dynamic airflow on human thermal response. https://app.cochat.ai/papers/10.1111/j.1600-0668.2006.00430.x
- The paper
- Zhou, X., Ouyang, Q., Lin, G., & Zhu, Y. (2006). Impact of dynamic airflow on human thermal response. Indoor Air. https://doi.org/10.1111/j.1600-0668.2006.00430.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.