The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils
Abstract
UNLABELLED: We investigated asthma and atopy in relation to microbial and plasticizer exposure. Pupils in eight primary schools in Uppsala (Sweden) answered a questionnaire, 1014 (68%) participated. Totally, 7.7% reported doctor-diagnosed asthma, 5.9% current asthma, and 12.2% allergy to pollen/pets. Wheeze was reported by 7.8%, 4.5% reported daytime breathlessness, and 2.0% nocturnal breathlessness. Measurements were performed in 23 classrooms (May-June), 74% had <1000 ppm CO(2) indoors. None had visible mold growth or dampness. Mean total microbial volatile organic compound (MVOC) concentration was 423 ng/m(3) indoors and 123 ng/m(3) outdoors. Indoor concentration of TMPD-MIB (2,2,4-trimethyl-1,3-pentanediol monoisobutyrate, Texanol) and TMPD-DIB (2,2,4-trimethyl-1,3-pentanediol diisobutyrate, TXIB), two common plasticizers, were 0.89 and 1.64 microg/m(3), respectively. MVOC and plasticizer concentration were correlated (r = 0.5; P < 0.01). Mold concentration was 360 cfu/m(3) indoors and 980 cfu/m(3) outdoors. At higher indoor concentrations of total MVOC, nocturnal breathlessness (P < 0.01) and doctor-diagnosed asthma (P < 0.05) were more common. Moreover, there were positive associations between nocturnal breathlessness and 3-methylfuran (P < 0.01), 3-methyl-1-butanol (P < 0.05), dimethyldisulfide (P < 0.01), 2-heptanone (P < 0.01), 1-octen-3-ol (P < 0.05), 3-octanone (P < 0.05), TMPD-MIB (P < 0.05), and TMPD-DIB (P < 0.01). TMPD-DIB was positively associated with wheeze (P < 0.05), daytime breathlessness (P < 0.05), doctor-diagnosed asthma (P < 0.05), and current asthma (P < 0.05). In conclusion, exposure to MVOC and plasticizers at school may be a risk factor for asthmatic symptoms in children. PRACTICAL IMPLICATIONS: Despite generally good ventilation and lack of visible signs of mold growth, we found an association between respiratory symptoms and indoor MVOC concentration. In addition, we found associations between asthmatic symptoms and two common plasticizers. The highest levels of MVOC, TMPD-MIB, and TMPD-DIB were found in two new buildings, suggesting that material emissions should be better controlled. As MVOC and plasticizers concentrations were positively correlated, while indoor viable molds and bacteria were negatively correlated, it is unclear if indoor MVOC is an indicator of microbial exposure. Further studies focusing on health effects of chemical emissions from indoor plastic materials, including PVC-floor coatings, are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hay fever, hygiene, and household size.
Strachan, D. P. (1989) · BMJ · doi:10.1136/bmj.299.6710.1259 · Cited by 5,054
Exposure to farming in early life and development of asthma and allergy: a cross-sectional survey
Riedler, J., Braun-Fahrländer, C., Eder, W., Schreuer, M., Waser, M., Maisch, S., Carr, D., Schierl, R., Nowak, D., & von Mutius, E. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06252-3 · Cited by 1,520
Bornehag, C. G., Sundell, J., Hagerhed-Engman, L., Sigsggard, T., Janson, S., Aberg, N., & DBH Study Group (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00306.x · Cited by 250
Cited by
Microbial Volatile Organic Compounds
Korpi, A., Järnberg, J., & Pasanen, A.-L. (2009) · Critical Reviews in Toxicology · doi:10.1080/10408440802291497 · Cited by 596
Human exposure, hazard and risk of alternative plasticizers to phthalate esters
Bui, T. T., Giovanoulis, G., Cousins, A. P., Magnér, J., Cousins, I. T., & de Wit, C. A. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.09.036 · Cited by 467
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Kanazawa, A., Saito, I., Araki, A., Takeda, M., Ma, M., Saijo, Y., & Kishi, R. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00629.x · Cited by 290
Indoor Air Quality and Sources in Schools and Related Health Effects
Annesi-Maesano, I., Baiz, N., Banerjee, S., Rudnai, P., Rive, S., & the SINPHONIE Group (2013) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2013.853609 · Cited by 281
Metadata
- Authors
- Kim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., & Norbäck, D.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2007-04
- Volume
- 17
- Issue
- 2
- Pages
- 153-163
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W1963549510
- Cited by
- 213
- References
- 3
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils. https://app.cochat.ai/papers/10.1111/j.1600-0668.2006.00466.x
- The paper
- Kim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., & Norbäck, D. (2007). Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils. Indoor Air. https://doi.org/10.1111/j.1600-0668.2006.00466.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.