Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils

Kim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., Norbäck, D.·2007·Indoor Air

Abstract

UNLABELLED: We investigated asthma and atopy in relation to microbial and plasticizer exposure. Pupils in eight primary schools in Uppsala (Sweden) answered a questionnaire, 1014 (68%) participated. Totally, 7.7% reported doctor-diagnosed asthma, 5.9% current asthma, and 12.2% allergy to pollen/pets. Wheeze was reported by 7.8%, 4.5% reported daytime breathlessness, and 2.0% nocturnal breathlessness. Measurements were performed in 23 classrooms (May-June), 74% had <1000 ppm CO(2) indoors. None had visible mold growth or dampness. Mean total microbial volatile organic compound (MVOC) concentration was 423 ng/m(3) indoors and 123 ng/m(3) outdoors. Indoor concentration of TMPD-MIB (2,2,4-trimethyl-1,3-pentanediol monoisobutyrate, Texanol) and TMPD-DIB (2,2,4-trimethyl-1,3-pentanediol diisobutyrate, TXIB), two common plasticizers, were 0.89 and 1.64 microg/m(3), respectively. MVOC and plasticizer concentration were correlated (r = 0.5; P < 0.01). Mold concentration was 360 cfu/m(3) indoors and 980 cfu/m(3) outdoors. At higher indoor concentrations of total MVOC, nocturnal breathlessness (P < 0.01) and doctor-diagnosed asthma (P < 0.05) were more common. Moreover, there were positive associations between nocturnal breathlessness and 3-methylfuran (P < 0.01), 3-methyl-1-butanol (P < 0.05), dimethyldisulfide (P < 0.01), 2-heptanone (P < 0.01), 1-octen-3-ol (P < 0.05), 3-octanone (P < 0.05), TMPD-MIB (P < 0.05), and TMPD-DIB (P < 0.01). TMPD-DIB was positively associated with wheeze (P < 0.05), daytime breathlessness (P < 0.05), doctor-diagnosed asthma (P < 0.05), and current asthma (P < 0.05). In conclusion, exposure to MVOC and plasticizers at school may be a risk factor for asthmatic symptoms in children. PRACTICAL IMPLICATIONS: Despite generally good ventilation and lack of visible signs of mold growth, we found an association between respiratory symptoms and indoor MVOC concentration. In addition, we found associations between asthmatic symptoms and two common plasticizers. The highest levels of MVOC, TMPD-MIB, and TMPD-DIB were found in two new buildings, suggesting that material emissions should be better controlled. As MVOC and plasticizers concentrations were positively correlated, while indoor viable molds and bacteria were negatively correlated, it is unclear if indoor MVOC is an indicator of microbial exposure. Further studies focusing on health effects of chemical emissions from indoor plastic materials, including PVC-floor coatings, are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2006.00466.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 213

Metadata

Authors
Kim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., & Norbäck, D.
Venue
Indoor Air
Published
2007-04
Volume
17
Issue
2
Pages
153-163
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W1963549510
Cited by
213
References
3
FWCI
7.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils. https://app.cochat.ai/papers/10.1111/j.1600-0668.2006.00466.x
The paper
Kim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., & Norbäck, D. (2007). Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools ? associations with asthma and respiratory symptoms in pupils. Indoor Air. https://doi.org/10.1111/j.1600-0668.2006.00466.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.