CoChat

Real-time or faster-than-real-time simulation of airflow in buildings

Zuo, W., Chen, Q. · 2009 · Indoor Air
Cited by 194

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Real-time flow simulation is crucial for emergency management in buildings, such as fire and accidental or intentional release of chemical/biological agents (contaminants). The simulation results can then be used to impose proper measures to minimize casualties. Computational fluid dynamics (CFD) is accurate, but too time-consuming. Nodal models are fast, but not informative. To obtain a quick and informative solution, this study proposes an intermediate approach between nodal models and CFD by introducing a fast fluid dynamics (FFD) method. This investigation used the FFD methods with and without turbulence treatments to study systematically four basic flows in buildings, and compared the numerical results with the corresponding CFD results and the data from the literature. The results show that, on one hand, the FFD can offer much richer flow information than nodal models, but less accurate results than CFD. On the other hand, the FFD is 50 times faster than the CFD. The results also show that the FFD with the laminar assumption has the best overall performance as regards both accuracy and speed. It is possible to conduct faster-than-real-time flow simulations with detailed flow information by using the FFD method. PRACTICAL IMPLICATIONS: The paper introduces a fast fluid dynamics (FFD) method, which can simulate airflow and contaminant dispersion in buildings with real-time or faster-than-real-time speed and provide informative solutions. As an intermediate approach between nodal models and the computational fluid dynamics (CFD), the FFD can be a very useful tool for emergency management in case of fire and accidental or intentional release of chemical or biological agents in a building or around the buildings. The FFD can also be used as a preliminary test tool for quick assessment of indoor airflows before a detailed CFD analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2008.00559.x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Metadata

Authors
Zuo, W., & Chen, Q.
Venue
Indoor Air
Published
2009-02
Volume
19
Issue
1
Pages
33-44
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2134967905
Cited by
194
References
15
FWCI
4.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time or faster-than-real-time simulation of airflow in buildings. https://app.cochat.ai/papers/10.1111/j.1600-0668.2008.00559.x
The paper
Zuo, W., & Chen, Q. (2009). Real-time or faster-than-real-time simulation of airflow in buildings. Indoor Air. https://doi.org/10.1111/j.1600-0668.2008.00559.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.