The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
CFD and ventilation research
Open accessAbstract
UNLABELLED: There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000-10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize the growing need for CFD verification and validation, suggest ongoing needs for analytical and experimental methods to support the numerical solutions, and discuss the growing capacity of CFD in opening up new research areas. We suggest that CFD has not become a replacement for experiment and theoretical analysis in ventilation research, rather it has become an increasingly important partner. PRACTICAL IMPLICATIONS: We believe that an effective scientific approach for ventilation studies is still to combine experiments, theory, and CFD. We argue that CFD verification and validation are becoming more crucial than ever as more complex ventilation problems are solved. It is anticipated that ventilation problems at the city scale will be tackled by CFD in the next 10 years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Self-citation
Cited by
Blocken, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.015 · Cited by 1,163
A review on the CFD analysis of urban microclimate
Toparlar, Y., Blocken, B., Maiheu, B., & van Heijst, G. J. F. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.248 · Cited by 759
LES over RANS in building simulation for outdoor and indoor applications: A foregone conclusion?
Blocken, B. (2018) · Building Simulation · doi:10.1007/s12273-018-0459-3 · Cited by 543
Passive cooling dissipation techniques for buildings and other structures: The state of the art
Santamouris, M., & Kolokotsa, D. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.11.002 · Cited by 446
Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278
Metadata
- Authors
- Li, Y., & Nielsen, P. V.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2011-07-04
- Volume
- 21
- Issue
- 6
- Pages
- 442-453
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2147278758
- Cited by
- 192
- References
- 1
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CFD and ventilation research. https://app.cochat.ai/papers/10.1111/j.1600-0668.2011.00723.x
- The paper
- Li, Y., & Nielsen, P. V. (2011). CFD and ventilation research. Indoor Air. https://doi.org/10.1111/j.1600-0668.2011.00723.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.