Glass ionomer and resin‐based fissure sealants: a clinical study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare the retention rate of a glass ionomer cement formulated for fissure sealing with two resin‐based sealants. 208 occlusal fissures of permanent molars and premolars were sealed with either Fuji III, Delton or Concise WS by four dentists. Clinical assessments and a replica scoring technique were used to register the performance of the sealants at baseline, after 6–12 months, and then yearly up to 5 yr. As judged clinically, 61% of the glass ionomer sealants were lost within 6–12 months and 84% after 30–36 months. Although total loss was recorded clinically for the majority of the glass ionomer sealants, some retained sealant was observed in the tooth replicas in 93%, of them. The clinical evaluation of the resin‐based sealants showed an average complete retention rate of 90% after 4.5–5 yr. The corresponding figure with the replica technique was 58%. Caries was recorded in 5% of the resin‐based and in none of the glass ionomer sealed surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The bonding of glass ionomer cements to metal and tooth substrates
Hotz, P., McLean, J. W., Sced, I., & Wilson, A. D. (1977) · British Dental Journal · doi:10.1038/sj.bdj.4803864 · Cited by 286
Clinical evaluation of a glass ionomer cement as a fissure sealant.
Boksman, L., Dr, G., McCutcheon, E., & Plotzke, O. B. (1987) · PubMed · Cited by 56
Cited by
Minimal intervention dentistry for managing dental caries – a review
Frencken, J. E., Peters, M. C., Manton, D. J., Leal, S. C., Gordan, V. V., & Eden, E. (2012) · International Dental Journal · doi:10.1111/idj.12007 · Cited by 531
Atraumatic Restorative Treatment (ART): Rationale, Technique, and Development
Frencken, J. E., Pilot, T., Songpaisan, Y., & Phantumvanit, P. (1996) · Journal of Public Health Dentistry · doi:10.1111/j.1752-7325.1996.tb02423.x · Cited by 439
Ahovuo-Saloranta, A., Hiiri, A., Nordblad, A., Mäkelä, M., & Worthington, H. V. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001830.pub3 · Cited by 408
Pit and fissure sealants for preventing dental decay in permanent teeth
Ahovuo-Saloranta, A., Forss, H., Walsh, T., Nordblad, A., Mäkelä, M., & Worthington, H. V. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001830.pub5 · Cited by 391
Sealants for preventing dental decay in the permanent teeth
Ahovuo-Saloranta, A., Forss, H., Walsh, T., Hiiri, A., Nordblad, A., Mäkelä, M., & Worthington, H. V. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001830.pub4 · Cited by 335
Twenty-five-year atraumatic restorative treatment (ART) approach: a comprehensive overview
Frencken, J. E., Leal, S. C., & Navarro, M. F. (2012) · Clinical Oral Investigations · doi:10.1007/s00784-012-0783-4 · Cited by 237
Advances in glass-ionomer cements
Davidson, C. L. (2006) · Journal of Applied Oral Science · doi:10.1590/s1678-77572006000700002 · Cited by 228
“The findings of Mejàre and Mjör (1990) that teeth sealed with resins more frequently develop caries than teeth sealed with glass-ionomer, in spite of the fact that the bulk glass-ionomer sealant had visually vanished within a few months, were explained by SEM-imaging, which revealed still retained…”
BackgroundSurvival of atraumatic restorative treatment (ART) sealants and restorations: a meta-analysis
de Amorim, R. G., Leal, S. C., & Frencken, J. E. (2012) · Clinical Oral Investigations · doi:10.1007/s00784-011-0513-3 · Cited by 213
“Many studies have shown resinbased sealant to have a high level of retention [27]; higher than those of low- and medium-viscosity glass ionomers [ 10 , 28].”
BackgroundThe Atraumatic Restorative Treatment (ART) approach for managing dental caries: a meta-analysis
van’t Hof, M. A., Frencken, J. E., Helderman, W. H. V. P., & Holmgren, C. J. (2006) · International Dental Journal · doi:10.1111/j.1875-595x.2006.tb00339.x · Cited by 207
ART restorations and glass ionomer sealants in Zimbabwe: survival after 3 years
Frencken, J. E., Makoni, F., & Sithole, W. D. (1998) · Community Dentistry and Oral Epidemiology · doi:10.1111/j.1600-0528.1998.tb01975.x · Cited by 167
The ART approach: clinical aspects reviewed
Molina, G. F., Cabral, R. J., & Frencken, J. E. (2009) · Journal of Applied Oral Science · doi:10.1590/s1678-77572009000700016 · Cited by 31
Metadata
- Authors
- MEJÀRE*, I., & MJÖR, I. A.
- Venue
- European Journal of Oral Sciences
- Publisher
- Wiley
- Published
- 1990-08
- Volume
- 98
- Issue
- 4
- Pages
- 345-350
- ISSN
- 0029-845X (ISSN-L)
- 0909-8836
- 1600-0722
- OpenAlex
- W2080544493
- Cited by
- 170
- References
- 2
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.