The DOI matches its Crossref record.
Clinical assessment of hip strength using a hand‐held dynamometer is reliable
Abstract
Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test–retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand‐held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1‐week interval in between by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3–12%. When the maximum value of four measurements was used, test–retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12 tests. No systematic differences were present. Standardized strength assessment procedures of hip ABD, ER, IR, FLEX, with test–retest measurement variation below 5%, hip ADD below 6% and hip EXT below 8%, make it possible to determine even small changes in hip strength at the individual level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Forefoot Strikers Exhibit Lower Running-Induced Knee Loading than Rearfoot Strikers
KULMALA, J.-P., AVELA, J., PASANEN, K., & PARKKARI, J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829efcf7 · Cited by 306
Assessment of the rate of force development scaling factor for the hip muscles
Casartelli, N. C., Lepers, R., & Maffiuletti, N. A. (2014) · Muscle & Nerve · doi:10.1002/mus.24229 · Cited by 36
Metadata
- Authors
- Thorborg, K., Petersen, J., Magnusson, S. P., & Hölmich, P.
- Venue
- Scandinavian Journal of Medicine & Science in Sports
- Publisher
- Wiley
- Published
- 2010-05-18
- Volume
- 20
- Issue
- 3
- Pages
- 493-501
- ISSN
- 0905-7188 (ISSN-L)
- 1600-0838
- OpenAlex
- W2115252012
- Cited by
- 518
- References
- 0
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical assessment of hip strength using a hand‐held dynamometer is reliable. https://app.cochat.ai/papers/10.1111/j.1600-0838.2009.00958.x
- The paper
- Thorborg, K., Petersen, J., Magnusson, S. P., & Hölmich, P. (2010). Clinical assessment of hip strength using a hand‐held dynamometer is reliable. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/j.1600-0838.2009.00958.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.