Clinical assessment of hip strength using a hand‐held dynamometer is reliable
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test–retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand‐held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1‐week interval in between by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3–12%. When the maximum value of four measurements was used, test–retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12 tests. No systematic differences were present. Standardized strength assessment procedures of hip ABD, ER, IR, FLEX, with test–retest measurement variation below 5%, hip ADD below 6% and hip EXT below 8%, make it possible to determine even small changes in hip strength at the individual level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105 · cited 1×
“Grubb’s test was used to detect outliers in the individual test, and these were removed (Grubbs, 1969; http://www. graphpad.com, 2008).”
Method(1950) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.1950.04040020187020 · Cited by 1,113
Hip Strength in Females With and Without Patellofemoral Pain
Ireland, M. L., Willson, J. D., Ballantyne, B. T., & Davis, I. M. (2003) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2003.33.11.671 · Cited by 780
Hölmich, P., Uhrskou, P., Ulnits, L., Kanstrup, I.-L., Nielsen, M. B., Bjerg, A. M., & Krogsgaard, K. (1999) · The Lancet · doi:10.1016/s0140-6736(98)03340-6 · Cited by 487
Self-citationTyler, T. F., Nicholas, S. J., Campbell, R. J., & McHugh, M. P. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290020301 · Cited by 428
Kendall, F., McCreary, E., & Provance, P. (1994) · Medicine and Science in Sports and Exercise · doi:10.1249/00005768-199408000-00023 · Cited by 366
Hip muscle strength and muscle cross sectional area in men with and without hip osteoarthritis.
Arokoski, M. H., Arokoski, J. P., Haara, M., Kankaanpaa, M. J., Vesterinen, M., Niemitukia, L. H., & Helminen, H. J. (2002) · PubMed · Cited by 301
Hip Muscle Weakness and Overuse Injuries in Recreational Runners
Niemuth, P. E., Johnson, R. J., Myers, M. J., & Thieman, T. J. (2005) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-200501000-00004 · Cited by 286
Hip Strength in Collegiate Female Athletes with Patellofemoral Pain
CICHANOWSKI, H. R., SCHMITT, J. S., JOHNSON, R. J., & NIEMUTH, P. E. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180601109 · Cited by 278
Kelln, B. M., McKeon, P. O., Gontkof, L. M., & Hertel, J. (2008) · Journal of Sport Rehabilitation · doi:10.1123/jsr.17.2.160 · Cited by 267
Strength testing with a portable dynamometer: reliability for upper and lower extremities.
Agre, J. C., Jl, M., Sz, H., Kc, W., Baxter, T., PATTERSON, R. P., & Stradel, L. (1987) · PubMed · Cited by 229
The Role of Hip Muscle Function in the Treatment of Patellofemoral Pain Syndrome
Tyler, T. F., Nicholas, S. J., Mullaney, M. J., & McHugh, M. P. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505281808 · Cited by 209
Pua, Y.-H., Wrigley, T. W., Cowan, S. M., & Bennell, K. L. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.10.028 · Cited by 205
Make Tests and Break Tests of Elbow Flexor Muscle Strength
Bohannon, R. W. (1988) · Physical Therapy · doi:10.1093/ptj/68.2.193 · Cited by 188
Dynamometry testing in spinal cord injury
Sisto, S. A., & Dyson‐Hudson, T. A. (2007) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.11.0172 · Cited by 171
Hölmich, P., Hölmich, L. R., & Bjerg, A. M. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.004754 · Cited by 168
Self-citationKrause, D. A., Schlagel, S. J., Stember, B. M., Zoetewey, J. E., & Hollman, J. H. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.09.011 · Cited by 135
Subject variability of shoulder abduction strength testing
Magnusson, S. P., Gleim, G. W., & Nicholas, J. A. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800403 · Cited by 82
Self-citationLu, T.-W., Hsu, H., Chang, L. Y., & Chen, H. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0107 · Cited by 69
Test–retest reliability of cardinal plane isokinetic hip torque and EMG
Claiborne, T. L., Timmons, M. K., & Pincivero, D. M. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.005 · Cited by 59
Cited by
Mentiplay, B. F., Perraton, L. G., Bower, K. J., Adair, B., Pua, Y.-H., Williams, G. P., McGaw, R., & Clark, R. A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140822 · Cited by 601
Jæger, P., Zaric, D., Fomsgaard, J. S., Hilsted, K. L., Bjerregaard, J., Gyrn, J., Mathiesen, O., Larsen, T. K., & Dahl, J. B. (2013) · Regional Anesthesia and Pain Medicine · doi:10.1097/aap.0000000000000015 · Cited by 333
Forefoot Strikers Exhibit Lower Running-Induced Knee Loading than Rearfoot Strikers
KULMALA, J.-P., AVELA, J., PASANEN, K., & PARKKARI, J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829efcf7 · Cited by 306
Thorborg, K., Bandholm, T., & Hölmich, P. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-012-2115-2 · Cited by 251
“(2010) [24] previously, including a detailed testprocedure appendix.”
BackgroundMethodInfluentialSelf-citationRisk Factors for Lower Extremity Injuries in Elite Female Soccer Players
Nilstad, A., Andersen, T. E., Bahr, R., Holme, I., & Steffen, K. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513518741 · Cited by 210
“97).(52,53) One Repetition Maximum Leg Press.”
Metadata
- Authors
- Thorborg, K., Petersen, J., Magnusson, S. P., & Hölmich, P.
- Venue
- Scandinavian Journal of Medicine & Science in Sports
- Publisher
- Wiley
- Published
- 2010-05-18
- Volume
- 20
- Issue
- 3
- Pages
- 493-501
- ISSN
- 0905-7188 (ISSN-L)
- 1600-0838
- OpenAlex
- W2115252012
- Cited by
- 518
- References
- 21
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.