Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 231

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cold Machine Perfusion Versus Static Cold Storage of Kidneys Donated After Cardiac Death: A UK Multicenter Randomized Controlled Trial

Open access
Watson, C.J.E, Wells, A.C, Roberts, R.J, Akoh, J.A, Friend, P.J, Akyol, M., Calder, F.R, Allen, J.E, Jones, M.N, Collett, D., Bradley, J.A · 2010 · American Journal of Transplantation

Abstract

One third of deceased donor kidneys for transplantation in the UK are donated following cardiac death (DCD). Such kidneys have a high rate of delayed graft function (DGF) following transplantation. We conducted a multicenter, randomized controlled trial to determine whether kidney preservation using cold, pulsatile machine perfusion (MP) was superior to simple cold storage (CS) for DCD kidneys. One kidney from each DCD donor was randomly allocated to CS, the other to MP. A sequential trial design was used with the primary endpoint being DGF, defined as the necessity for dialysis within the first 7 days following transplant. The trial was stopped when data were available for 45 pairs of kidneys. There was no difference in the incidence of DGF between kidneys assigned to MP or CS (58% vs. 56%, respectively), in the context of an asystolic period of 15 min and median cold ischemic times of 13.9 h for MP and 14.3 h for CS kidneys. Renal function at 3 and 12 months was similar between groups, as was graft and patient survival. For kidneys from controlled DCD donors (with mean cold ischemic times around 14 h), MP offers no advantage over CS, which is cheaper and more straightforward.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-6143.2010.03165.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 231

Metadata

Authors
Watson, C. J. E., Wells, A. C., Roberts, R. J., Akoh, J. A., Friend, P. J., Akyol, M., Calder, F. R., Allen, J. E., Jones, M. N., Collett, D., & Bradley, J. A.
Venue
American Journal of Transplantation
Publisher
Elsevier BV
Published
2010-09
Volume
10
Issue
9
Pages
1991-1999
ISSN
1600-6135 (ISSN-L)
OpenAlex
W2125104239
Cited by
231
References
1
FWCI
21.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cold Machine Perfusion Versus Static Cold Storage of Kidneys Donated After Cardiac Death: A UK Multicenter Randomized Controlled Trial. https://app.cochat.ai/papers/10.1111/j.1600-6143.2010.03165.x
The paper
Watson, C. J. E., Wells, A. C., Roberts, R. J., Akoh, J. A., Friend, P. J., Akyol, M., Calder, F. R., Allen, J. E., Jones, M. N., Collett, D., & Bradley, J. A. (2010). Cold Machine Perfusion Versus Static Cold Storage of Kidneys Donated After Cardiac Death: A UK Multicenter Randomized Controlled Trial. American Journal of Transplantation. https://doi.org/10.1111/j.1600-6143.2010.03165.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.