CoChat

High-Intensity Interval Training Improves Peak Oxygen Uptake and Muscular Exercise Capacity in Heart Transplant Recipients

Open access
Nytrøen, K., Rustad, L.A., Aukrust, P., Ueland, T., Hallén, J., Holm, I., Rolid, K., Lekva, T., Fiane, A.E., Amlie, J.P., Aakhus, S., Gullestad, L. · 2012 · American Journal of Transplantation
Cited by 116

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Heart transplant (HTx) recipients usually have reduced exercise capacity with reported VO(2peak) levels of 50-70% predicted value. Our hypothesis was that high-intensity interval training (HIIT) is an applicable and safe form of exercise in HTx recipients and that it would markedly improve VO(2peak.) Secondarily, we wanted to evaluate central and peripheral mechanisms behind a potential VO(2peak) increase. Forty-eight clinically stable HTx recipients >18 years old and 1-8 years after HTx underwent maximal exercise testing on a treadmill and were randomized to either exercise group (a 1-year HIIT-program) or control group (usual care). The mean ± SD age was 51 ± 16 years, 71% were male and time from HTx was 4.1 ± 2.2 years. The mean VO(2peak) difference between groups at follow-up was 3.6 [2.0, 5.2] mL/kg/min (p < 0.001). The exercise group had 89.0 ± 17.5% of predicted VO(2peak) versus 82.5 ± 20.0 in the control group (p < 0.001). There were no changes in cardiac function measured by echocardiography. We have demonstrated that a long-term, partly supervised and community-based HIIT-program is an applicable, effective and safe way to improve VO(2peak) , muscular exercise capacity and general health in HTx recipients. The results indicate that HIIT should be more frequently used among stable HTx recipients in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-6143.2012.04221.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 116

Metadata

Authors
Nytrøen, K., Rustad, L. A., Aukrust, P., Ueland, T., Hallén, J., Holm, I., Rolid, K., Lekva, T., Fiane, A. E., Amlie, J. P., Aakhus, S., & Gullestad, L.
Venue
American Journal of Transplantation
Publisher
Elsevier BV
Published
2012-11
Volume
12
Issue
11
Pages
3134-3142
ISSN
1600-6135 (ISSN-L)
OpenAlex
W2117498656
Cited by
116
References
3
FWCI
12.86
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Intensity Interval Training Improves Peak Oxygen Uptake and Muscular Exercise Capacity in Heart Transplant Recipients. https://app.cochat.ai/papers/10.1111/j.1600-6143.2012.04221.x
The paper
Nytrøen, K., Rustad, L. A., Aukrust, P., Ueland, T., Hallén, J., Holm, I., Rolid, K., Lekva, T., Fiane, A. E., Amlie, J. P., Aakhus, S., & Gullestad, L. (2012). High-Intensity Interval Training Improves Peak Oxygen Uptake and Muscular Exercise Capacity in Heart Transplant Recipients. American Journal of Transplantation. https://doi.org/10.1111/j.1600-6143.2012.04221.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.