Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of the ability of thermal and electrical tests to register pulp vitality

Peterson, K., Söderström, C., Kiani‐Anaraki, M., Lévy, G. · 1999 · Dental Traumatology

Abstract

The aim of the present study was to evaluate the ability of thermal and electrical tests to register pulp vitality. Sensitivity, specificity, negative predictive value and positive predictive value were calculated by comparing the test results with a “gold standard”. The thermal tests studied were a cold test (ethyl chloride) and a heat test (hot gutta‐percha). For the electrical test, the Analytic Technology Pulp Tester® was used. The examined teeth were 59 teeth with unknown pulpal status in need of endodontic treatment and 16 intact teeth, all with radiographically normal periapical bone structures. In total 46 teeth with vital pulps and 29 teeth with necrotic pulps were tested. This gave a disease prevalence of 39%. The gold standard was established by direct pulp inspection of the 59 teeth in need of endodontic treatment. In the 16 intact teeth the pulp was judged as vital. The number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) test results was calculated for each method as compared to the gold standard. Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The sensitivity was 0.83 for the cold test, 0.86 for the heat test and 0.72 for the electrical test. The specificity was 0.93 for the cold test, 0.41 for the heat test and 0.93 for the electrical test. The positive predictive value was 0.89 for the cold test, 0.48 for the heat test and 0.88 for the electrical test, and the negative predictive value was 0.90 for the cold test, 0.83 for the heat test and 0.84 for the electrical test. This indicated that the probability of a non‐sensitive reaction representing a necrotic pulp was 89% with the cold test, 48% with the heat test and 88% with the electrical test. It also indicated that the probability of a sensitive reaction representing a vital pulp was 90% with the cold test, 83% with the heat test and 84% with the electrical test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-9657.1999.tb00769.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 242

Metadata

Authors
Peterson, K., Söderström, C., Kiani‐Anaraki, M., & Lévy, G.
Venue
Dental Traumatology
Publisher
Wiley
Published
1999-06
Volume
15
Issue
3
Pages
127-131
ISSN
  • 1600-4469 (ISSN-L)
  • 1600-9657
OpenAlex
W2096075721
Cited by
242
References
1
FWCI
6.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the ability of thermal and electrical tests to register pulp vitality. https://app.cochat.ai/papers/10.1111/j.1600-9657.1999.tb00769.x
The paper
Peterson, K., Söderström, C., Kiani‐Anaraki, M., & Lévy, G. (1999). Evaluation of the ability of thermal and electrical tests to register pulp vitality. Dental Traumatology. https://doi.org/10.1111/j.1600-9657.1999.tb00769.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.