Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Low‐energy laser stimulates tooth movement velocity via expression of RANK and RANKL

Fujita, S, Yamaguchi, M, Utsunomiya, T, Yamamoto, H, Kasai, K · 2008 · Orthodontics & Craniofacial Research

Abstract

Structured Abstract: Authors – Fujita S, Yamaguchi M, Utsunomiya T, Yamamoto H, Kasai K Objective – Recent studies have demonstrated that low‐energy laser irradiation stimulates bone formation in vitro and in vivo. However, very little is known about the effects of laser irradiation on osteoclastogenesis. The receptor activator of the nuclear factor‐k B (RANK) / RANK ligand (RANKL) / osteoprotegerin (OPG) system is essential and sufficient for osteoclastogenesis. The present study was designed to examine the effects of low‐energy laser irradiation on expressions of RANK, RANKL, and OPG during experimental tooth movement. Design – To induce experimental tooth movement in rats, 10 g of orthodontic force was applied to the molars. Next, a Ga–Al–As diode laser was used to irradiate the area around the moved tooth and the amount of tooth movement was measured for 7 days. Immunohistochemical staining with RANK, RANKL, and OPG was performed. Real time PCR was also performed to elucidate the expression of RANK in irradiated rat osteoclast precursor cells in vitro. Results – In the irradiation group, the amount of tooth movement was significantly greater than in the non‐irradiation group by the end of the experimental period. Cells that showed positive immunoreactions to the primary antibodies of RANKL and RANK were significantly increased in the irradiation group on day 2 and 3, compared with the non‐irradiation group. In contrast, the expression of OPG was not changed. Further, RANK expression in osteoclast precursor cells was detected at an early stage (day 2 and 3) in the irradiation group. Conclusion – These findings suggest that low‐energy laser irradiation stimulates the velocity of tooth movement via induction of RANK and RANKL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1601-6343.2008.00423.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 211

Metadata

Authors
Fujita, S., Yamaguchi, M., Utsunomiya, T., Yamamoto, H., & Kasai, K.
Venue
Orthodontics & Craniofacial Research
Publisher
Wiley
Published
2008-07-11
Volume
11
Issue
3
Pages
143-155
ISSN
  • 1601-6335 (ISSN-L)
  • 1601-6343
OpenAlex
W1974986201
Cited by
211
References
2
FWCI
4.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low‐energy laser stimulates tooth movement velocity via expression of RANK and RANKL. https://app.cochat.ai/papers/10.1111/j.1601-6343.2008.00423.x
The paper
Fujita, S., Yamaguchi, M., Utsunomiya, T., Yamamoto, H., & Kasai, K. (2008). Low‐energy laser stimulates tooth movement velocity via expression of RANK and RANKL. Orthodontics & Craniofacial Research. https://doi.org/10.1111/j.1601-6343.2008.00423.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.