The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reproducibility of facial soft tissue landmarks on 3D laser‐scanned facial images
Abstract
Structured Abstract: Authors – Toma AM, Zhurov A, Playle R, Ong E, Richmond S Background – The three‐dimensional (3D) measuring technology is useful to inspect facial shape in three planes of space (X, Y, and Z). Recent work has been directed to analyse craniofacial morphology using facial soft tissue landmarks to identify facial differences among population. The reproducibility of facial landmarks is almost necessary to ensure accurate 3D facial measurements. Objective – The aim of this study is to assess the reproducibility of facial soft tissue landmarks using laser‐scan 3D imaging technology. Subjects and Methods – Facial landmarks were assessed for 30 15½‐year‐old British‐Caucasian children (15 males and 15 females). The sample was recruited from the Avon Longitudinal Study of Parents and Children (ALSPAC). The 3D facial images were acquired for each subject using two high‐resolution Konica/Minolta laser scanners. Twenty‐one facial landmarks (63 X, Y, and Z coordinates) were identified and recorded on each 3D facial image by two examiners. The reproducibility of landmarks identification at 2‐week interval was assessed for one of the examiners (intra‐examiner). In addition, the reproducibility of landmarks was assessed between the two examiners (inter‐examiner). Using Bland‐Altman plots, both intra‐ and inter‐examiner assessments had evaluated landmarks reproducibility in three dimensions for the sample divided by gender. The reproducibility of the 3D‐coordinates for each landmark was considered under three categories (< 0.5 mm, < 1 mm, and >1 mm) for both intra‐ and inter‐examiner reproducibility assessments. Results – The distribution of coordinates at the three levels of reproducibility show the following percentages: intra‐examiner: < 0.5 mm (38%), < 1 mm (51%), >1 mm (11%); inter‐examiner: < 0.5 mm (35%), < 1 mm (48%), >1 mm (17%). Generally, 10 landmarks were reproducible to less than 1 mm for both intra‐ and inter‐examiner reproducibility assessments. The Labiale Superius was the most reproducible and Palebrale Superius was the least reproducible landmark. Some landmarks showed greater reliability in certain planes of space; the Glabella was more reliable in the Z than the Y axis. Gender differences were found; Subnasale was more reproducible in the Y‐axis in males compared with females. Conclusions – The reproducibility of facial landmarks should be considered in the three planes of space. The majority of X‐Y‐Z coordinates taken to the 21 facial landmarks were reproducible to < 1 mm which is clinically acceptable. The accuracy of landmarks identification ranged from 0.39 to 1.49 mm. The reliability in identification depends on the clarity and definition of each landmark as well as gender characteristics. The different landmarks reproducibility should be considered when evaluating changes related to growth and healthcare interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Novel genetic loci affecting facial shape variation in humans
Xiong, Z., Dankova, G., Howe, L. J., Lee, M. K., Hysi, P. G., de Jong, M. A., Zhu, G., Adhikari, K., Li, D., Li, Y., et al. (2019) · eLife · doi:10.7554/elife.49898 · Cited by 92
Self-citation3D Analysis of the Cranial and Facial Shape in Craniosynostosis Patients: A Systematic Review
Kurniawan, M. S. I. C., Tio, P. A. E., Abdel Alim, T., Roshchupkin, G., Dirven, C. M. F., Pleumeekers, M. M., Mathijssen, I. M. J., & van Veelen, M.-L. C. (2024) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000010071 · Cited by 16
Metadata
- Authors
- Toma, A., Zhurov, A., Playle, R., Ong, E., & Richmond, S.
- Venue
- Orthodontics & Craniofacial Research
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 12
- Issue
- 1
- Pages
- 33-42
- ISSN
- 1601-6335 (ISSN-L)
- 1601-6343
- OpenAlex
- W1985555687
- Cited by
- 187
- References
- 1
- FWCI
- 13.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of facial soft tissue landmarks on 3D laser‐scanned facial images. https://app.cochat.ai/papers/10.1111/j.1601-6343.2008.01435.x
- The paper
- Toma, A., Zhurov, A., Playle, R., Ong, E., & Richmond, S. (2009). Reproducibility of facial soft tissue landmarks on 3D laser‐scanned facial images. Orthodontics & Craniofacial Research. https://doi.org/10.1111/j.1601-6343.2008.01435.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.