A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous Maxillae

D'haese, Jan, Van De Velde, Tommie, Elaut, Lucien, De Bruyn, Hugo·2012·Clinical Implant Dentistry and Related Research

Abstract

Background: Flapless implant placement using guided surgery is widespread, although clinical publications on the precision are lacking. Purpose: The purpose of this study was to evaluate the accuracy of mucosal‐supported stereolithographic guides in the edentulous maxillae. Materials and Methods: Seventy‐eight OsseoSpeed™ implants (Astra Tech AB, Mölndal, Sweden) of 3.5 to 5 mm width and 8 to 15 mm length were installed consecutively in 13 patients. Implants were functionally loaded on the day of surgery, and implant location was assessed with a computed tomography scan. Mimics 9.0 software (Materialise N.V., Leuven, Belgium) was used to fuse the images of the virtually planned and actually placed implants, and the locations, axes, and interimplant distances were compared. Results: One implant was lost shortly after insertion because of abscess formation caused by remnants of impression material. Seventy‐seven implant locations were analyzed. The deviation at the entrance point ranged between 0.29 mm and 2.45 mm (SD: 0.44 mm), with a mean of 0.91 mm. Average angle deviation was 2.60° (range 0.16–8.86°; SD: 1.61°). At the apical point, the deviation ranged between 0.32 mm and 3.01 mm, with a mean of 1.13 mm (SD: 0.52 mm). The mean deviation of the coronal and apical interimplant distance was respectively 0.18 mm (range 0.07–0.32 mm; SD: 0.15) and 0.33 mm (range 0.12–0.69 mm; SD: 0.28). These deviations are lower than the global coronal and apical deviations. Conclusion: The present study is the first to investigate the accuracy of stereolithographic, full, mucosally supported surgical guides in the treatment of fully edentulous maxillae. Clinicians should be warned that angular and linear deviations are to be expected. Short implants show significantly lower apical deviations compared with longer ones. Reasons for implant deviations are multifactorial; however, it is unlikely that the production process of the guide has a major impact on the total accuracy of a mucosal‐supported stereolithographic guide.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1708-8208.2009.00255.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
D'haese, J., Van De Velde, T., Elaut, L., & De Bruyn, H.
Venue
Clinical Implant Dentistry and Related Research
Publisher
Wiley
Published
2012-03-22
Volume
14
Issue
2
Pages
293-303
ISSN
  • 1523-0899 (ISSN-L)
  • 1708-8208
OpenAlex
W1914712329
Cited by
163
References
0
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous Maxillae. https://app.cochat.ai/papers/10.1111/j.1708-8208.2009.00255.x
The paper
D'haese, J., Van De Velde, T., Elaut, L., & De Bruyn, H. (2012). A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous Maxillae. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/j.1708-8208.2009.00255.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.