CoChat

Multi‐micronutrient Sprinkles including a low dose of iron provided as microencapsulated ferrous fumarate improves haematologic indices in anaemic children: a randomized clinical trial

Open access
Christofides, Anna, Asante, Kwaku Poku, Schauer, Claudia, Sharieff, Waseem, Owusu‐Agyei, Seth, Zlotkin, Stanley · 2006 · Maternal & Child Nutrition
Cited by 89

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Home‐fortification of complementary foods with micronutrients (including iron) as Sprinkles is a new strategy to control iron deficiency and anaemia in developing countries. However, the most effective dose and form of iron is not known. The purpose of this study was to compare the efficacy of various doses (12.5, 20 or 30 mg) and treatment methods (multi‐micronutrient Sprinkles vs. ferrous sulphate drops) on haemoglobin (Hb) concentration after 8 weeks of treatment in anaemic children. In total, 133 anaemic Ghanaian children (Hb 70–99 g L−1) aged 6–18 months were randomly assigned to one of five daily interventions for 8 weeks. Out of the five interventions, four used Sprinkles, and one used iron drops. Of the four Sprinkles groups, three included 12.5, 20 or 30 mg of iron as ferrous fumarate, and one included 20 mg of iron as ferric pyrophosphate. The iron drops group included 12.5 mg of iron as liquid ferrous sulphate. Hb concentrations were measured at baseline, week 3 and week 8. The primary outcome measure was Hb concentration at 8 weeks after treatment. We compared differences in Hb and ferritin concentrations and prevalence of iron deficiency anaemia (Hb < 100 g L−1 and soluble transferrin receptor concentrations >8.5 mg L−1) from baseline to 8 weeks within and between groups. Adherence and reporting of side effects (staining of the teeth, ease of use, diarrhoea and darkening of stools) were compared between groups. Mean change in Hb was 1.4 g L−1 (SD = 1.8) (P = 0.0001). Change in Hb concentrations from baseline to 8 weeks was significant in all groups (P = 0.0001–0.0007), with no differences across groups. Geometric means of serum ferritin varied from 18.6 to 44.0 µg L−1 at baseline. At week 8, these means were in the interval of 48.0–78.3 µg L−1, with no group differences. Prevalence of iron deficiency anaemia decreased significantly from baseline to 8 weeks in all groups with the exception of the iron drops group, with no group differences. Adherence was lower in the drops group (64%) as compared with Sprinkles groups (84%). Greater staining of the teeth and less ease of use were reported in the drops group as compared with Sprinkles groups. A dose as low as 12.5 mg of iron as ferrous fumarate when provided as Sprinkles may be effective in anaemic children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1740-8709.2006.00060.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 89

Metadata

Authors
Christofides, A., Asante, K. P., Schauer, C., Sharieff, W., Owusu‐Agyei, S., & Zlotkin, S.
Venue
Maternal & Child Nutrition
Publisher
Wiley
Published
2006-06
Volume
2
Issue
3
Pages
169-180
ISSN
  • 1740-8695 (ISSN-L)
  • 1740-8709
OpenAlex
W2108923809
Cited by
89
References
2
FWCI
2.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.