CoChat

Can serum mast cell tryptase help diagnose anaphylaxis?

Brown, Simon GA, Blackman, Konrad E, Heddle, Robert J · 2004 · Emergency Medicine
Cited by 136

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective: We aimed to determine the utility of serum mast cell tryptase to diagnose anaphylaxis. Methods: As part of a venom immunotherapy trial, we performed 64 sting challenges. Blood samples were taken before the sting (baseline), and 15 min and 60 min after the sting. Tryptase was measured in baseline, 15 minute and 60 minute serum samples. Histamine was measured in baseline and 15 minute plasma samples. Eleven people had undisputed severe anaphylactic reactions; tryptase and histamine levels were assessed against this clinical gold standard diagnosis. Results: Excluding mild reactions from the analysis, peak tryptase readings had sensitivity of 0.36 and specificity of 0.93 using the recommended cut‐off range (< 12.0 µg/L). Receiver‐operator curve analysis found a cut‐off of 9.0 µg/L would improve diagnostic performance (sensitivity 0.55, specificity 0.93). Serial tryptase measurement was significantly more discriminatory; an increase in tryptase of 2.0 µg/L or greater had a sensitivity of 0.73 and specificity of 0.98. The addition of histamine measurements, defining a positive result by either a rise in tryptase or a rise in histamine, appeared to further increase sensitivity (0.90). Conclusions: Clinicians should use caution when using serum tryptase to refute or support a diagnosis of anaphylaxis. Serial tryptase measurement increases sensitivity and specificity. Further studies using serial tryptase determinations in general emergency department practice, perhaps supplemented by histamine determinations, are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1742-6723.2004.00562.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 136

Metadata

Authors
Brown, S. G., Blackman, K. E., & Heddle, R. J.
Venue
Emergency Medicine
Publisher
Wiley
Published
2004-04
Volume
16
Issue
2
Pages
120-124
ISSN
  • 1035-6851 (ISSN-L)
  • 1442-2026
OpenAlex
W2060728864
Cited by
136
References
4
FWCI
4.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can serum mast cell tryptase help diagnose anaphylaxis? https://app.cochat.ai/papers/10.1111/j.1742-6723.2004.00562.x
The paper
Brown, S. G., Blackman, K. E., & Heddle, R. J. (2004). Can serum mast cell tryptase help diagnose anaphylaxis? Emergency Medicine. https://doi.org/10.1111/j.1742-6723.2004.00562.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.