Characterization of an in vitro model for evaluating the interface between skin and percutaneous biomaterials
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Percutaneous devices play an essential role in medicine; however, they are often associated with a significant risk of infection. One approach to circumvent infection would be to heal the wound around the devices by promoting skin cell attachment. We used two in vitro assay models to evaluate cutaneous response to poly(2‐hydoxyethyl methacrylate) (poly(HEMA)). One approach was to use a cell adhesion assay to test the effects of surface modification of poly(HEMA), and the second used an organ culture system of newborn foreskin biopsies implanted with porous poly(HEMA) rods (20 μm pores) to evaluate the skin/poly(HEMA) interface. Surface modification of poly(HEMA) using 1,1′‐carbonyldiimidazole (CDI) enhanced keratinocyte, fibroblast, and endothelial cell adhesion. Keratinocytes in the organ culture model not only remained functionally and structurally viable as observed by immunohistochemistry and electron microscopy, but migrated into the pores of CDI‐modified poly(HEMA) rods. No biointegration was seen in the non‐CDI‐modified poly(HEMA). Laminin 5 immunostaining was seen along the poly(HEMA)/skin interface in a pattern resembling the junctional epithelium of the tooth, the unique natural interface between the skin and tooth that serves as a barrier to bacteria. In vitro systematic evaluation of biomaterials for use in animal implant studies is both cost effective and time efficient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Cited by
Griffin, D. R., Weaver, W. M., Scumpia, P. O., Di Carlo, D., & Segura, T. (2015) · Nature Materials · doi:10.1038/nmat4294 · Cited by 981
Zhao, G., Hochwalt, P. C., Usui, M. L., Underwood, R. A., Singh, P. K., James, G. A., Stewart, P. S., Fleckman, P., & Olerud, J. E. (2010) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2010.00608.x · Cited by 275
“Six-micrometer sections of OCT-embedded implant specimens were immunolabeled using routine immunoperoxidase methods as described previously.(19) Primary antibodies used were: Pankeratin (Panker) (rabbit, 1 : 1,000, Dako, Carpenteria, CA), Keratin 14 (K14) (rabbit, 1 : 1,000, Covance, Princeton, NJ), platelet/endotheli…”
Self-citationEngineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
“Similar successes with a polyHEMA PTS for regeneration of skin at a percutaneous wound site have been recently published (Fukano et al., 2006, 2010; Isenhath et al., 2007; Knowles et al., Biotechnol Bioeng.”
ResultSelf-citationHernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Inverse Opal Scaffolds and Their Biomedical Applications
Zhang, Y. S., Zhu, C., & Xia, Y. (2017) · Advanced Materials · doi:10.1002/adma.201701115 · Cited by 182
Metadata
- Authors
- Fukano, Y., Knowles, N. G., Usui, M. L., Underwood, R. A., Hauch, K. D., Marshall, A. J., Ratner, B. D., Giachelli, C., Carter, W. G., Fleckman, P., & Olerud, J. E.
- Venue
- Wound Repair and Regeneration
- Publisher
- Wiley
- Published
- 2006-07
- Volume
- 14
- Issue
- 4
- Pages
- 484-491
- ISSN
- 1067-1927 (ISSN-L)
- 1524-475X
- OpenAlex
- W1995320683
- Cited by
- 62
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.