Complications of Therapeutic Plasma Exchange: Experience With 4857 Treatments
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Plasma exchange (PE) is a technique of extracorporeal blood purification which removes large molecular weight substances from plasma. The Department of Dialysis, Zagreb University Hospital Center's database, which includes data on 509 patients, or 4857 PE treatments, was retrospectively analyzed to test the safety of PE. A total of 231 adverse reactions were recorded (4.75% of treatments). The most common complications were paresthesias (2.7%), hematoma at the puncture site (2.4%), clotting (1.7%), mild to moderate allergic reactions (urticaria; 1.6%) and bleeding (0.06%). True anaphylactoid reactions were recorded in five procedures. The incidence of severe, potentially life‐threatening adverse reactions was 0.12%. The prophylactic use of calcium and potassium was responsible for a low incidence of electrolyte disturbances. There was no lethal outcome associated with PE. When carried out by experienced staff, PE is a relatively safe procedure. The use of fresh frozen plasma is associated with a higher rate of adverse reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
INCIDENCE AND SEVERITY OF ANAPHYLACTOID REACTIONS TO COLLOID VOLUME SUBSTITUTES
Ring, J., & Messmer, K. (1977) · The Lancet · doi:10.1016/s0140-6736(77)91953-5 · Cited by 1,299 · cited 1×
“Our results are comparable with those reported from other studies, where most reactions were limited to rigor or urticaria (3,5,22,23).”
ResultTherapeutic Plasma Exchange: Complications and Management
Mokrzycki, M. H., & Kaplan, A. A. (1994) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(12)80135-1 · Cited by 303 · cited 1×
“Our results are comparable with those reported from other studies, where most reactions were limited to rigor or urticaria (3,5,22,23).”
ResultComplications of plasma exchange
Sutton, D. M. C., Nair, R. C., Rock, G., & Canadian Apheresis Study Group (1989) · Transfusion · doi:10.1046/j.1537-2995.1989.29289146829.x · Cited by 195
Atypical reactions associated with use of angiotensin‐converting enzyme inhibitors and apheresis
Owen, H. G., & Brecher, M. E. (1994) · Transfusion · doi:10.1046/j.1537-2995.1994.341095026976.x · Cited by 145 · cited 2×
“ACEI should be withheld for at least 24 h before apheresis (25).”
BackgroundThe Complications of Therapeutic Plasma Exchange
Ziselman, E. M., Bongiovanni, M. B., & Wurzel, H. A. (1984) · Vox Sanguinis · doi:10.1111/j.1423-0410.1984.tb00086.x · Cited by 50
Cited by
EULAR/ERA-EDTA recommendations for the management of ANCA-associated vasculitis
Yates, M., Watts, R. A., Bajema, I. M., Cid, M. C., Crestani, B., Hauser, T., Hellmich, B., Holle, J. U., Laudien, M., Little, M. A., et al. (2016) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-209133 · Cited by 1,194
Complications of therapeutic plasma exchange: A prospective study of 1,727 procedures
Shemin, D., Briggs, D., & Greenan, M. (2007) · Journal of Clinical Apheresis · doi:10.1002/jca.20143 · Cited by 240
“Reactions of any kind were more common with FFP replacement compared to albumin and saline replacement [16].”
BackgroundMagro-Checa, C., Zirkzee, E. J., Huizinga, T. W., & Steup-Beekman, G. M. (2016) · Drugs · doi:10.1007/s40265-015-0534-3 · Cited by 235
Anticoagulation techniques in apheresis: From heparin to citrate and beyond
Lee, G., & Arepally, G. M. (2012) · Journal of Clinical Apheresis · doi:10.1002/jca.21222 · Cited by 204
Winters, J. L. (2012) · Hematology · doi:10.1182/asheducation.v2012.1.7.3797920 · Cited by 188
Metadata
- Authors
- Basic‐Jukic, N., Kes, P., Glavas‐Boras, S., Brunetta, B., Bubic‐Filipi, L., & Puretic, Z.
- Venue
- Therapeutic Apheresis and Dialysis
- Publisher
- Wiley
- Published
- 2005-09-30
- Volume
- 9
- Issue
- 5
- Pages
- 391-395
- ISSN
- 1091-6660 (ISSN-L)
- 1744-9979
- 1744-9987
- OpenAlex
- W2147409187
- Cited by
- 185
- References
- 5
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.