The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Long‐Term Performance of Permeable Reactive Barriers Using Zero‐Valent Iron: Geochemical and Microbiological Effects
Abstract
Geochemical and microbiological factors that control long‐term performance of subsurface permeable reactive barriers were evaluated at the Elizabeth City, North Carolina, and the Denver Federal Center, Colorado, sites. These ground water treatment systems use zero‐valent iron filings (Peerless Metal Powders Inc.) to intercept and remediate chlorinated hydrocarbon compounds at the Denver Federal Center (funnel‐and‐gate system) and overlapping plumes of hexavalent chromium and chlorinated hydrocarbons at Elizabeth City (continuous wall system). Zero‐valent iron at both sites is a long‐term sink for carbon, sulfur, calcium, silicon, nitrogen, and magnesium. After about four years of operation, the average rates of inorganic carbon (IC) and sulfur (S) accumulation are 0.09 and 0.02 kg/m 2 /year, respectively, at Elizabeth City where upgradient waters contain <400 mg/L of total dissolved solids (TDS). At the Denver Federal Center site, upgradient ground water contains 1000 to 1200 mg/L TDS and rates of IC and S accumulation are as high as 2.16 and 0.80 kg/m 2 /year, respectively. At both sites, consistent patterns of spatially variable mineral precipitation and microbial activity are observed. Mineral precipitates and microbial biomass accumulate the fastest near the upgradient aquifer‐Fe 0 interface. Maximum net reductions in porosity due to the accumulation of sulfur and inorganic carbon precipitates range from 0.032 at Elizabeth City to 0.062 at the Denver Federal Center (gate 2) after about four years. Although pore space has been lost due the accumulation of authigenic components, neither site shows evidence of pervasive pore clogging after four years of operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics of Chromate Reduction by Ferrous Iron
Fendorf, S. E., & Li, G. (1996) · Environmental Science & Technology · doi:10.1021/es950618m · Cited by 397
Vogan, J. L., Focht, R. M., Clark, D. K., & Graham, S. L. (1999) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(99)00033-3 · Cited by 181
Cited by
Guan, X., Sun, Y., Qin, H., Li, J., Lo, I. M. C., He, D., & Dong, H. (2015) · Water Research · doi:10.1016/j.watres.2015.02.034 · Cited by 962
Sun, Y., Li, J., Huang, T., & Guan, X. (2016) · Water Research · doi:10.1016/j.watres.2016.05.031 · Cited by 495
Fan, D., Lan, Y., Tratnyek, P. G., Johnson, R. L., Filip, J., O’Carroll, D. M., Nunez Garcia, A., & Agrawal, A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b04177 · Cited by 472
Long-Term Performance of Zero-Valent Iron Permeable Reactive Barriers: A Critical Review
Henderson, A. D., & Demond, A. H. (2007) · Environmental Engineering Science · doi:10.1089/ees.2006.0071 · Cited by 456
Hexavalent Chromium Reduction with Zero-Valent Iron (ZVI) in Aquatic Systems
Gheju, M. (2011) · Water, Air, & Soil Pollution · doi:10.1007/s11270-011-0812-y · Cited by 359
Metadata
- Authors
- Wilkin, R. T., Puls, R. W., & Sewell, G. W.
- Venue
- Groundwater
- Publisher
- Wiley
- Published
- 2003-07
- Volume
- 41
- Issue
- 4
- Pages
- 493-503
- ISSN
- 0017-467X (ISSN-L)
- 1745-6584
- OpenAlex
- W1970117816
- Cited by
- 219
- References
- 2
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long‐Term Performance of Permeable Reactive Barriers Using Zero‐Valent Iron: Geochemical and Microbiological Effects. https://app.cochat.ai/papers/10.1111/j.1745-6584.2003.tb02383.x
- The paper
- Wilkin, R. T., Puls, R. W., & Sewell, G. W. (2003). Long‐Term Performance of Permeable Reactive Barriers Using Zero‐Valent Iron: Geochemical and Microbiological Effects. Groundwater. https://doi.org/10.1111/j.1745-6584.2003.tb02383.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.