Conduction Velocity and Amplitude of the Action Potential as Related to Circumference in the Isolated Fibre of Frog Muscle
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Summary.: 1. Conduction velocity and amplitude of the action potential and fibre circumference were measured in isolated frog muscle fibres in a large volume of Ringer's solution. 2. Conduction velocity was found to be a linear function of fibre circumference. 3. The velocity in a fibre of 100 μ diameter (circumference 314 μ) at 20°C was 2.44 & 0.05 m/sec. for spring frogs and 2.05 & 0.07 m/sec. for winter frogs. The total range in eonduction velocity at 20°C was 1.2–3.1 m/sec. for spring frogs and 1.0–2.76 m/sec. for winter frogs. 4. The amplitude of the action potential, both at constant distance from the fibre surface and at 500 μ from the midpoint of the fibre, was relatively greater in fibres with large than in fibres with small circumference. 5. The amplitude decreased steeply with electrode distance from the fibre up to 200 μ, and reached one tenth of the maximally measured value at a distance of about 600 μ. At equal distance the amplitude was 20 per cent smaller when the electrode faced the rounded side of an elliptical fibre, than when it faced the flat surface (large diameter twice the small). 6. The findings with respect to conduction velocity and amplitude as a function of circumference are interpreted to indicate that the specific electrical properties of the membrane differ according to fibre size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory of the effects of fibre size in medullated nerve
Rushton, W. A. H. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004655 · Cited by 1,075
CONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916
AXON DIAMETERS IN RELATION TO THE SPIKE DIMENSIONS AND THE CONDUCTION VELOCITY IN MAMMALIAN A FIBERS
Gasser, H. S., & Grundfest, H. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.2.393 · Cited by 454
Gasser, H. S., & Erlanger, J. (1927) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1927.80.3.522 · Cited by 326
Hodgkin, A. L. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005152 · Cited by 262
A COMPARISON OF THE CHARACTERISTICS OF AXONS THROUGH THEIR INDIVIDUAL ELECTRICAL RESPONSES
Blair, E. A., & Erlanger, J. (1933) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1933.106.3.524 · Cited by 247
NATURE OF THE "ENDPLATE POTENTIAL" IN CURARIZED MUSCLE
Eccles, J. C., Katz, B., & Kuffler, S. W. (1941) · Journal of Neurophysiology · doi:10.1152/jn.1941.4.5.362 · Cited by 232
The sodium and potassium content of cephalopod nerve fibres
Keynes, R. D., & Lewis, P. R. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004609 · Cited by 216
UNMEDULLATED FIBERS ORIGINATING IN DORSAL ROOT GANGLIA
Gasser, H. S. (1950) · The Journal of General Physiology · doi:10.1085/jgp.33.6.651 · Cited by 207
The electrical properties of the muscle fibre membrane
Katz, B. (1948) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1948.0027 · Cited by 196
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
The relation between the surface electromyogram and muscular force.
Milner‐Brown, H. S., & Stein, R. B. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010904 · Cited by 644
Effects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Andreassen, S., & Arendt-Nielsen, L. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016756 · Cited by 353
Myoelectric signal conduction velocity and spectral parameters: influence of force and time
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1428 · Cited by 260
Standards for quantification of EMG and neurography
Stålberg, E., van Dijk, H., Falck, B., Kimura, J., Neuwirth, C., Pitt, M., Podnar, S., Rubin, D. I., Rutkove, S., Sanders, D. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.05.008 · Cited by 254
Inference of motor unit recruitment order in voluntary and electrically elicited contractions
Knaflitz, M., Merletti, R., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.4.1657 · Cited by 251
Bilodeau, M., Schindler-Ivens, S., Williams, D. M., Chandran, R., & Sharma, S. S. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00050-0 · Cited by 249
“This estimate, which corresponds to the 8% difference observed for the increase in MPF or MF with force of the VL between men and women in the present study, was obtained with the assumptions that conduction velocity is proportional to fiber circumference [13] and that there is a proportional change in MF or MPF for a…”
ResultWang, S., Nie, Y., Zhu, H., Xu, Y., Cao, S., Zhang, J., Li, Y., Wang, J., Ning, X., & Kong, D. (2022) · Science Advances · doi:10.1126/sciadv.abl5511 · Cited by 246
Multielectrode Study of the Territory of a Motor Unit
BUCHTHAL, F., GULD, C., & ROSENFALCK, P. (1957) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1957.tb01411.x · Cited by 233
Quantitative Motor Unit Potential Analysis
Stålberg, E., Nandedkar, S. D., Sanders, D. B., & Falck, B. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199609000-00004 · Cited by 227
Fibre conduction velocity and fibre composition in human vastus lateralis
Sadoyama, T., Masuda, T., Miyata, H., & Katsuta, S. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf01076001 · Cited by 224
Spontaneous electrical activity of human muscle
Buchthal, F., & Rosenfalck, P. (1966) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(66)90001-0 · Cited by 187
Farina, D., Muhammad, W., Fortunato, E., Meste, O., Merletti, R., & Rix, H. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02344807 · Cited by 181
Associations between motor unit action potential parameters and surface EMG features
Del Vecchio, A., Negro, F., Felici, F., & Farina, D. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00482.2017 · Cited by 176
Mannion, A. F. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00010-3 · Cited by 170
“[35] Håkansson CH.”
BackgroundMotor unit recruitment for dynamic tasks: current understanding and future directions
Hodson-Tole, E. F., & Wakeling, J. M. (2009) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0289-1 · Cited by 145
Miller, J. D., Lippman, J. D., Trevino, M. A., & Herda, T. J. (2020) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003694 · Cited by 34
“the diameter of muscle fibers within a MU (14).”
Background
Metadata
- Authors
- HAKANSSON, C. H.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1956-01
- Volume
- 37
- Issue
- 1
- Pages
- 14-34
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2038289422
- Cited by
- 223
- References
- 21
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.