Single Unit Analysis of Mechanoreceptor Activity from the Human Glabrous Skin
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Single unit impulses were recorded from the median and the ulnar nerves in waking human subjects with percutaneously inserted tungsten electrodes. 61 mechanoreceptor units in the glabrous skin were analysed with regard to the characteristics of their receptive fields and the basic physiological properties of their endings. 4 different types of receptors could be distinguished. This distinction was based mainly upon the adaptation and the receptive field characteristics although other differences were also observed. The fields had very sharp borders for the majority of the slowly as well as the rapidly adapting units. The field sizes varied considerably: between 10 mm 2 and 600 mm 2. For a minority of the receptors, slowly as well as rapidly adapting ones, the receptive fields were constituted of a center of high sensitivity and a wide surrounding area of lower sensitivity without distinct borders. The four types of receptors encountered in the present study have striking similarities with four different types of mechano‐receptors which have been described in sub‐human primates, namely the type I and type II slowly adapting, intradermal receptor, according to Iggo's terminology, an intradermal rapidly adapting receptor and the Pacinian corpuscle which is located in the subcutaneous tissues. Roughly 75% of the units were slowly adapting. This is a much larger proportion than found in the monkey. Further, it was shown how the recording method offers the opportunity to analyse the perceptive responses as well as the neurophysiological responses in first order neurons to mechanical stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Cancer Institute (2020) · Definitions · doi:10.32388/bz83sn · Cited by 2,981
Talbot, W. H., Darian-Smith, I., Kornhuber, H. H., & Mountcastle, V. B. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.2.301 · Cited by 990
The structure and function of a slowly adapting touch corpuscle in hairy skin
Iggo, A., & Muir, A. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008721 · Cited by 817
Evoked action potentials and conduction velocity in human sensory nerves
Buchthal, F., & Rosenfalck, A. (1966) · Brain Research · doi:10.1016/0006-8993(66)90056-4 · Cited by 756
Activity from skin mechanoreceptors recorded percutaneously in awake human subjects
Vallbo, Å. B., & Hagbarth, K.-E. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90041-1 · Cited by 530
Self-citationWerner, G., & Mountcastle, V. B. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.2.359 · Cited by 485
Pulse and Respiratory Grouping of Sympathetic Impulses in Human Muscle Nerves
Hagbarth, K. ‐., & Vallbo, Å. B. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.1968.tb10904.x · Cited by 441
Self-citationA quantitative study of cutaneous receptors and afferent fibres in the cat and rabbit
Brown, A. G., & Iggo, A. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008390 · Cited by 370
Cutaneous thermoreceptors in primates and sub‐primates
Iggo, A. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008701 · Cited by 353
Receptor types in cat hairy skin supplied by myelinated fibers.
Burgess, P. R., Petit, D., & Warren, R. M. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.6.833 · Cited by 330
AFFERENT IMPULSES IN CUTANEOUS SENSORY NERVES IN HUMAN SUBJECTS
Hensel, H., & Boman, K. K. A. (1960) · Journal of Neurophysiology · doi:10.1152/jn.1960.23.5.564 · Cited by 322
The impulses produced by sensory nerve endings: Part 3. Impulses set up by Touch and Pressure
Adrian, E. D., & Zotterman, Y. (1926) · The Journal of Physiology · doi:10.1113/jphysiol.1926.sp002308 · Cited by 271
Hunt, C. C., & McIntyre, A. K. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006521 · Cited by 229
Discharge characteristics of human muscle afferents during muscle stretch and contraction
Hagbarth, K.-E., & Vallbo, Å. B. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90156-8 · Cited by 204
Self-citationPROPERTIES OF TOUCH RECEPTORS IN DISTAL GLABROUS SKIN OF THE MONKEY
Lindblom, U. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.5.966 · Cited by 142
Slowly Adapting Muscle Receptors in Man
Vallbo, A. B. (1970) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1970.tb04667.x · Cited by 101
Single Unit Recordings from Muscle Nerves in Human Subjects
Hagbarth, K. ‐., & Vallbo, A. B. (1969) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1969.tb04475.x · Cited by 100
The discharge from vibration-sensitive receptors in the monkey foot
Lindblom, U., & Lund, L. (1966) · Experimental Neurology · doi:10.1016/0014-4886(66)90138-5 · Cited by 89
(1967) · PubMed · Cited by 68
The Neural Transformation of Mechanical Stimuli Delivered to the Monkey's Hand
Mountcastle, V. B., Talbot, W. H., & Kornhuber, H. H. (2008) · Novartis Foundation symposium · doi:10.1002/9780470715338.ch19 · Cited by 40
Cutaneous Receptors with a High Sensitivity to Mechanical Displacement
Iggo, A. (2008) · Novartis Foundation symposium · doi:10.1002/9780470715338.ch14 · Cited by 20
Cited by
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Lederman, S. J., & Klatzky, R. L. (2009) · Attention, Perception & Psychophysics · doi:10.3758/app.71.7.1439 · Cited by 1,108
“…(Bensmaïa & Hollins, 2005) Stable precision grasp and manipulation (Westling & Johansson, 1987) SA II Sustained downward pressure, lateral skin stretch (Knibestöl & Vallbo, 1970); low dynamic sensitivity (Johansson et al., 1982) Direction of object motion and force due to skin stretch (Olausson,…”
Background(1984) · PubMed · Cited by 908
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Tactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 784
Metadata
- Authors
- Knibestöl, M., & Vallbo, Å. B.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1970-10
- Volume
- 80
- Issue
- 2
- Pages
- 178-195
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2032947987
- Cited by
- 281
- References
- 21
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.