Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record.

Force and EMG signal patterns during repeated bouts of concentric or eccentric muscle actions

TESCH, P. A., DUDLEY, G. A., DUVOISIN, M. R., HATHER, B. M., HARRIS, R.T.·1990·Acta Physiologica Scandinavica

Abstract

Healthy males (n= 14) performed three bouts of 32 unilateral, maximal voluntary concentric (CON) or eccentric (ECC) quadriceps muscle actions on separate days. Surface electromyography (EMG) of the m. vastus lateralis (VL) and m. rectus femoris (RF) and torque were measured. Integrated EMG (IEMG), mean (MPF) and median power frequencies and torque were averaged for seven separate blocks of four consecutive muscle actions. Torque was greater (P < 0.05) for ECC than for CON muscle actions at the start of exercise. It did not decline throughout ECC exercise, but decreased (P < 0.05) markedly for each bout and over bouts of CON exercise. Thus, torque overall was substantially greater (P < 0.05) for ECC than for CON exercise. At the start of exercise IEMG of VL or RF was greater (P < 0.05) for CON than for ECC muscle actions. This was also true for overall IEMG activity during exercise. The IEMG increased (P < 0.05) modestly for both muscles during each bout of CON or ECC muscle actions, but did not change for the VL over bouts. The IEMG of RF decreased (P < 0.05) modestly over CON but not ECC exercise bouts. At the beginning of the first bout of exercise the IEMG/torque ratio was twofold greater (P < 0.05) for CON than ECC muscle actions. The ratio of IEMG/torque increased (P < 0.05) markedly during CON but did not change during ECC exercise. Thus, by the end of the third bout there was a fivefold difference (P < 0.05). The MPF decreased (P < 0.05) substantially in each CON bout with only a partial recovery between bouts. In contrast, MPF remained the same within each bout and over bouts of ECC exercise. These results indicate that the ability to maintain force during repeated bouts of maximal voluntary muscle actions at a relatively high angular velocity is remarkably greater for eccentric than for concentric exercise. It is suggested that the factors responsible for fatigue and for changes in the EMG signal pattern during concentric exercise do not materialize during, or are different for, eccentric exercise as performed here.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1748-1716.1990.tb08846.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 299

Metadata

Authors
TESCH, P. A., DUDLEY, G. A., DUVOISIN, M. R., HATHER, B. M., & HARRIS, R. T.
Venue
Acta Physiologica Scandinavica
Publisher
Wiley
Published
1990-03
Volume
138
Issue
3
Pages
263-271
ISSN
  • 0001-6772 (ISSN-L)
  • 1365-201X
OpenAlex
W2115225161
Cited by
299
References
0
FWCI
2.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Force and EMG signal patterns during repeated bouts of concentric or eccentric muscle actions. https://app.cochat.ai/papers/10.1111/j.1748-1716.1990.tb08846.x
The paper
TESCH, P. A., DUDLEY, G. A., DUVOISIN, M. R., HATHER, B. M., & HARRIS, R. T. (1990). Force and EMG signal patterns during repeated bouts of concentric or eccentric muscle actions. Acta Physiologica Scandinavica. https://doi.org/10.1111/j.1748-1716.1990.tb08846.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.