CoChat

Validation of the ‘internal reference technique’ for calibrating microdialysis catheters in situ

LÖNNROTH, P., STRINDBERG, L. · 1995 · Acta Physiologica Scandinavica
Cited by 86

The DOI matches its Crossref record.

Abstract

In vivo calibration of microdialysis catheters with [3 H]glucose as internal reference was done in rat (n= 17) and human (n= 12) subcutaneous tissue. The estimated interstititial glucose level was compared owth the glucose concentration in venous plasma which, in turn, has been shown to be identical to the interstitial glucose concentration. In subcutaneous tissue of anaesthetized male Sprageue‐Dawley rats, interstitial glucose was significantly overestimated (43%, P < 0.005, n= 8, and 19%, P < 0.005, n=9, in nornoglycaemic and hyperglycaemic animals, respectively). Furthermore, fractional outflux of [3 H]glucose decreased continuously during prolonged perfusion of the microdialysis catheter. Incontrast, in human subcutaneous tissue microdialysed with two catheters, correct measurements of interstitial glucose could be achieved and the precision was comparableto that obtained with equilibration calibraton in vivo. The average relative error of the mean result of two catheters was 8.9% at a perfusate flow rate of 1 μL min‐1. It may be suggested that calibration in in vivo of microdialysis catheters with internal references may be used in human subcutaneous tissue. However, it is necessary to validate the calibration technique in each different tissue under reproducible experimental conditions since accumulation of the reference substance in the tissue may create artefactual results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1748-1716.1995.tb09875.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 86

Metadata

Authors
LÖNNROTH, P., & STRINDBERG, L.
Venue
Acta Physiologica Scandinavica
Publisher
Wiley
Published
1995-04
Volume
153
Issue
4
Pages
375-380
ISSN
  • 0001-6772 (ISSN-L)
  • 1365-201X
OpenAlex
W1971268898
Cited by
86
References
0
FWCI
3.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the ‘internal reference technique’ for calibrating microdialysis catheters in situ. https://app.cochat.ai/papers/10.1111/j.1748-1716.1995.tb09875.x
The paper
LÖNNROTH, P., & STRINDBERG, L. (1995). Validation of the ‘internal reference technique’ for calibrating microdialysis catheters in situ. Acta Physiologica Scandinavica. https://doi.org/10.1111/j.1748-1716.1995.tb09875.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.