Redistribution of body fluids during postural manipulations
The DOI matches its Crossref record.
Abstract
Inter‐compartmental body‐fluid distribution is contingent upon posture, exercise state and environmental temperature. This investigation aimed at quantifying the distribution of intra‐ and extravascular fluid volumes during postural manipulations. Fluid shifts were measured in eight males utilizing a simultaneous, radionuclide dilution technique, in which radioiodinated serum fibrinogen, radiochromated crythrocytes, radiobromine and tritiated water were used to measure plasma, red cell, extracellular and total body water volumes. Subjects were exposed to three postural changes [seated (control), supine and standing] for 30 min at an air temperature of 22.0 d̀C, with each posture separated by 30 min seated rest. Total body water content remained stable throughout postural changes (P= 0.842). Relative to seated volumes, BV increased by 89 mL when supine, and decreased by 406 mL while standing (P= 0.003), with such shifts being primarily a result of plasma movement (P= 0.011). Red cell volume changes were not significant. Vascular fluid lost during standing was filtered into the interstitial compartment (P= 0.014), with the extracellular and intracellular volumes remaining unaffected (P= 0.271 and P= 0.800, respectively). These observations confirmed the influence of posture on inter‐compartmental body‐fluid distribution. The intravascular fluid loss when standing was caused by the filtration of plasma into the interstitium, while, during supine rest, intravascular volume increased, reflecting fluid flux from the interstitium to the circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yumino, D., Redolfi, S., Ruttanaumpawan, P., Su, M.-C., Smith, S., Newton, G. E., Mak, S., & Bradley, T. D. (2010) · Circulation · doi:10.1161/circulationaha.109.902452 · Cited by 452
Relationship between Overnight Rostral Fluid Shift and Obstructive Sleep Apnea in Nonobese Men
Redolfi, S., Yumino, D., Ruttanaumpawan, P., Yau, B., Su, M.-C., Lam, J., & Bradley, T. D. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200807-1076oc · Cited by 406
Clinical characteristics influencing bioelectrical impedance analysis measurements
Kushner, R., Gudivaka, R., & Schoeller, D. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.423s · Cited by 338
Taylor, N. A. S. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130022 · Cited by 331
Self-citationFriedman, O., Bradley, T. D., Chan, C. T., Parkes, R., & Logan, A. G. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.154427 · Cited by 213
Metadata
- Authors
- MAW, G. J., MACKENZIE, I. L., & TAYLOR, N. A. S.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 155
- Issue
- 2
- Pages
- 157-163
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2016071220
- Cited by
- 115
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Redistribution of body fluids during postural manipulations. https://app.cochat.ai/papers/10.1111/j.1748-1716.1995.tb09960.x
- The paper
- MAW, G. J., MACKENZIE, I. L., & TAYLOR, N. A. S. (1995). Redistribution of body fluids during postural manipulations. Acta Physiologica Scandinavica. https://doi.org/10.1111/j.1748-1716.1995.tb09960.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.