Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis system
The DOI matches its Crossref record.
Abstract
Summary: Automation of differentials is desirable for economic and time‐saving reasons. Over the last 20 years, automated imaging processes have started to be introduced where stained blood films are scanned by a computer‐driven microscope and leucocytes classified; however, early methods were slow and had difficulty in classifying abnormal cells. More recently the CellaVision™ DM96 (CellaVision AB, Lund, Sweden) has been introduced with added features such as continuous loading of slides and a faster throughput than previous instruments. The accuracy of CellaVision TM DM96 has been evaluated by comparing results to reference manual differentials. Results from different operators using the DM96 were compared with their own manual differential and to a 400‐cell reference manual differential. Precision of the instrument was compared to the manual differential. The preclassification accuracy of the DM96 was 89.2%. Precision was similar to that of the 100‐cell manual differential. The DM96 was faster than the manual method, even after reclassification by a laboratory scientist of any cells wrongly categorized by the instrument. The DM96 accuracy in morphological classification of leucocytes and red blood cells; depends upon both blood pathology and experience of the laboratory scientist using the instrument. For some cell types and operators, DM96 accuracy was better than the individual’s 100 cell manual differential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic Haematological Techniques
Briggs, C., & Bain, B. J. (2017) · Dacie and Lewis Practical Haematology · doi:10.1016/b978-0-7020-6696-2.00003-5 · Cited by 213
Self-citationRise of the Machines: Advances in Deep Learning for Cancer Diagnosis
Levine, A. B., Schlosser, C., Grewal, J., Coope, R., Jones, S. J. M., & Yip, S. (2019) · Trends in Cancer · doi:10.1016/j.trecan.2019.02.002 · Cited by 201
Matek, C., Krappe, S., Münzenmayer, C., Haferlach, T., & Marr, C. (2021) · Blood · doi:10.1182/blood.2020010568 · Cited by 191
“8 9-11 Furthermore, examination of individual cell morphologies is inherently qualitative, which makes the method dif fi cult to combine with other diagnostic methods that offer more quantitative data.”
MethodDigital morphology analyzers in hematology: ICSH review and recommendations
Kratz, A., Lee, S., Zini, G., Riedl, J. A., Hur, M., Machin, S., & the International Council for Standardization in Haematology (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13042 · Cited by 190
Self-citationInternational Council for Standardization in Haematology, W. G., Briggs, C., Culp, N., Davis, B., d'Onofrio, G., Zini, G., Machin, S. J., & the International Council for Standardization of Haematology (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12201 · Cited by 185
“Digital imaging analysis for all blood cells has also been shown to be equivalent to manual microscopy with improved traceability as all significant images can be re-reviewed and stored for future reference [1], but these too must be evaluated for both normal and pathological samples before introduction into clinical…”
BackgroundSelf-citationArtificial intelligence in healthcare: A bibliometric analysis
Jimma, B. L. (2023) · Telematics and Informatics Reports · doi:10.1016/j.teler.2023.100041 · Cited by 133
Bigorra, L., Merino, A., Alférez, S., & Rodellar, J. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22024 · Cited by 53
“(3) reported that the preclassifying agreement for blast cell class in Cellavision DM96 was at 76.”
BackgroundVery Deep Convolutional Neural Networks for Morphologic Classification of Erythrocytes
Durant, T. J. S., Olson, E. M., Schulz, W. L., & Torres, R. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.276345 · Cited by 49
Metadata
- Authors
- BRIGGS, C., LONGAIR, I., SLAVIK, M., THWAITE, K., MILLS, R., THAVARAJA, V., FOSTER, A., ROMANIN, D., & MACHIN, S. J.
- Venue
- International Journal of Laboratory Hematology
- Publisher
- Wiley
- Published
- 2009-01-11
- Volume
- 31
- Issue
- 1
- Pages
- 48-60
- ISSN
- 1751-5521 (ISSN-L)
- 1751-553X
- OpenAlex
- W1590583116
- Cited by
- 154
- References
- 0
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.