CoChat

Assessing the Validity of the Omron HEM‐907XL Oscillometric Blood Pressure Measurement Device in a National Survey Environment

Open access
Ostchega, Yechiam, Nwankwo, Tatiana, Sorlie, Paul D., Wolz, Michael, Zipf, George · 2010 · The Journal of Clinical Hypertension
Cited by 105

The DOI matches its Crossref record.

Abstract

J Clin Hypertens (Greenwich). 2010;12:22–28. ©2009 Wiley Periodicals, Inc. Blood pressure (BP) readings taken by Omron HEM‐907XL were compared with the results obtained using sphygmomanometer (HgS) in 509 individuals using 2002 Association for the Advancement of Medical Instrumentation (AAMI) criteria. With the exception of diastolic BP in youth ages 13 to 19 years (mean difference, −1.77 mm Hg; standard deviation, 8.65), the Omron device met the criteria. Agreement for hypertension (BP ≥140/90 mm Hg) was above chance (κ=0.68) and, compared with HgS, Omron underestimated the prevalence of hypertension by 2.65%. The Omron and HgS measurements were highly correlated (r=0.94 for systolic BP and r=0.83 for diastolic BP). Both increased systolic and diastolic BP decreased device agreement (β‐coefficient=−0.10872, P<.0001; β‐coefficient=−0.25981, P<.0001, respectively). The Omron device meets AAMI criteria with the exception of diastolic BP in youth ages 13 to 19 years. However, Omron underestimated the prevalence of hypertension and device agreement decreases with increased systolic and diastolic BP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1751-7176.2009.00199.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 105

Metadata

Authors
Ostchega, Y., Nwankwo, T., Sorlie, P. D., Wolz, M., & Zipf, G.
Venue
The Journal of Clinical Hypertension
Publisher
Wiley
Published
2009-12-28
Volume
12
Issue
1
Pages
22-28
ISSN
  • 1524-6175 (ISSN-L)
  • 1751-7176
OpenAlex
W2025313163
Cited by
105
References
0
FWCI
2.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing the Validity of the Omron HEM‐907XL Oscillometric Blood Pressure Measurement Device in a National Survey Environment. https://app.cochat.ai/papers/10.1111/j.1751-7176.2009.00199.x
The paper
Ostchega, Y., Nwankwo, T., Sorlie, P. D., Wolz, M., & Zipf, G. (2010). Assessing the Validity of the Omron HEM‐907XL Oscillometric Blood Pressure Measurement Device in a National Survey Environment. The Journal of Clinical Hypertension. https://doi.org/10.1111/j.1751-7176.2009.00199.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.